vl53l0x_read_raw() starts a single-shot ranging measurement and reads
back the result. Once the triggered buffer is enabled the sensor runs in
continuous mode and its data-ready interrupt is routed to the trigger,
so a concurrent in_distance_raw read disturbs the streaming setup and
never gets its completion, returning -ETIMEDOUT.
The original submission claimed direct mode here, but it was dropped
during review because the driver had no buffer support at the time [1].
Continuous (buffered) mode was later added without restoring the
claim [2], reintroducing the conflict.
Reject direct reads while buffered capture is active by claiming direct
mode around the measurement, as the vl53l1x sibling already does.
Fixes: 762186c6e7b1 ("iio: proximity: vl53l0x-i2c: Added continuous mode support")
Link: https://lore.kernel.org/linux-iio/20180911160300.GA9212@himanshu-Vostro-3559/ [1]
Link: https://lore.kernel.org/linux-iio/20240909101508.263085-3-abhashkumarjha123@gmail.com/ [2]
Signed-off-by: Donggeun Yoo <donggeunyoo.kernel@gmail.com>
Cc: stable@vger.kernel.org
Signed-off-by: Jonathan Cameron <jonathan.cameron@oss.qualcomm.com>
|