PCI: Add pci_irq_type() to query the allocated interrupt typegrafted
Add a helper that returns PCI_IRQ_MSIX, PCI_IRQ_MSI, or PCI_IRQ_INTX based on the interrupt type the PCI core selected after pci_alloc_irq_vectors(). Several drivers already open-code this check against pdev->msix_enabled and pdev->msi_enabled, or even open code this helper [1]. A common helper avoids the duplication and keeps drivers from accessing the bitfield directly (see also [2]). Acked-by: Bjorn Helgaas <bhelgaas@google.com> Tested-by: John Hubbard <jhubbard@nvidia.com> Link: https://elixir.bootlin.com/linux/v7.1/source/drivers/net/ethernet/aquantia/atlantic/aq_pci_func.c#L196 [1] Inspired-by: John Hubbard <jhubbard@nvidia.com> Link: https://lore.kernel.org/all/DKKG2QM3YJYB.Z2H2B2UXJ75N@kernel.org/ [2] Reviewed-by: Gary Guo <gary@garyguo.net> Link: https://patch.msgid.link/20260813165234.620555-5-dakr@kernel.org [ Add missing pci_irq_type() stub for CONFIG_PCI=n. ] Signed-off-by: Danilo Krummrich <dakr@kernel.org>
Diffstat (limited to 'fs/befs/inode.c')
-rw-r--r--fs/befs/inode.c55
1 files changed, 55 insertions, 0 deletions
diff --git a/fs/befs/inode.c b/fs/befs/inode.c
new file mode 100644
index 000000000..791b46a6f
--- /dev/null
+++ b/fs/befs/inode.c
@@ -0,0 +1,55 @@
+// SPDX-License-Identifier: GPL-2.0
+/*
+ * inode.c
+ *
+ * Copyright (C) 2001 Will Dyson <will_dyson@pobox.com>
+ */
+
+#include <linux/fs.h>
+
+#include "befs.h"
+#include "inode.h"
+
+/*
+ * Validates the correctness of the befs inode
+ * Returns BEFS_OK if the inode should be used, otherwise
+ * returns BEFS_BAD_INODE
+ */
+int
+befs_check_inode(struct super_block *sb, befs_inode *raw_inode,
+ befs_blocknr_t inode)
+{
+ u32 magic1 = fs32_to_cpu(sb, raw_inode->magic1);
+ befs_inode_addr ino_num = fsrun_to_cpu(sb, raw_inode->inode_num);
+ u32 flags = fs32_to_cpu(sb, raw_inode->flags);
+
+ /* check magic header. */
+ if (magic1 != BEFS_INODE_MAGIC1) {
+ befs_error(sb,
+ "Inode has a bad magic header - inode = %lu",
+ (unsigned long)inode);
+ return BEFS_BAD_INODE;
+ }
+
+ /*
+ * Sanity check2: inodes store their own block address. Check it.
+ */
+ if (inode != iaddr2blockno(sb, &ino_num)) {
+ befs_error(sb, "inode blocknr field disagrees with vfs "
+ "VFS: %lu, Inode %lu", (unsigned long)
+ inode, (unsigned long)iaddr2blockno(sb, &ino_num));
+ return BEFS_BAD_INODE;
+ }
+
+ /*
+ * check flag
+ */
+
+ if (!(flags & BEFS_INODE_IN_USE)) {
+ befs_error(sb, "inode is not used - inode = %lu",
+ (unsigned long)inode);
+ return BEFS_BAD_INODE;
+ }
+
+ return BEFS_OK;
+}