summaryrefslogtreecommitdiffstats
path: root/drivers/thermal/intel/Kconfig
diff options
context:
space:
mode:
authorTim Chen <tim.c.chen@linux.intel.com>2026-09-21 17:37:22 -0700
committerIngo Molnar <mingo@kernel.org>2026-09-22 10:49:53 +0200
commit0d6526f82c3cdefcca47f73f5fc08dc6f335eac6 (patch)
tree176dc2d685debcfb082c151ee94f2425ac96b364 /drivers/thermal/intel/Kconfig
downloadlinux-stable-0d6526f82c3cdefcca47f73f5fc08dc6f335eac6.tar.gz
linux-stable-0d6526f82c3cdefcca47f73f5fc08dc6f335eac6.zip
sched/cache: Keep nr_pref_llc_running in the runnable domain, to fix LLC mis-scheduling buggrafted
alb_break_llc() decides whether to break LLC preference during active load balance. It does so by testing that every runnable fair task on the source rq prefers its LLC: env->src_rq->nr_pref_llc_running == env->src_rq->cfs.h_nr_runnable But the two counters cover different sets. nr_pref_llc_running is updated in account_llc_enqueue()/account_llc_dequeue(), next to cfs_rq->nr_queued, so it follows queued tasks. h_nr_runnable is updated in set_delayed()/ clear_delayed() and drops delay-dequeued tasks. So under DELAY_DEQUEUE, a preferring task that goes to sleep stays counted in nr_pref_llc_running while h_nr_runnable falls. The equality then breaks, alb_break_llc() returns false, and active balance is free to pull a task off its preferred LLC. Active balance only moves runnable tasks, and this is the only LLC check it consults: once the stopper runs, LBF_ACTIVE_LB skips the per-task test in can_migrate_task(). The runnable set is the one we want. Fix it on the counter side. A task should be counted in nr_pref_llc_running exactly while it is both queued on its preferred LLC (pref_llc_queued) and runnable (!sched_delayed). Define that membership once in task_pref_llc_runnable(), and adjust the counter only through pref_llc_running_inc()/pref_llc_running_dec() from the four sites that change either input: account_llc_enqueue(), account_llc_dequeue(), set_delayed() and clear_delayed(). Gating every update on the same predicate keeps the delay, wake and dequeue paths from double-counting or underflowing; see the comments at those sites for the ordering. nr_llc_running and sd->llc_counts are not touched and stay on queued semantics. Fixes: 714059f79ff0 ("sched/cache: Handle moving single tasks to/from their preferred LLC") Closes: https://lore.kernel.org/lkml/20260827135000.735138-1-zhanxusheng@xiaomi.com/ Reported-by: Zhan Xusheng <zhanxusheng@xiaomi.com> Suggested-by: Chen Yu <yu.c.chen@intel.com> Signed-off-by: Tim Chen <tim.c.chen@linux.intel.com> Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org> Signed-off-by: Ingo Molnar <mingo@kernel.org> Reviewed-by: Kayra Cizmeci <kayracizmeci@gmail.com> Cc: <stable@kernel.org> # v7.2.x Link: https://patch.msgid.link/06af61afedac32e6477f57feb4d658f6c411c3af.1790035273.git.tim.c.chen@linux.intel.com
Diffstat (limited to 'drivers/thermal/intel/Kconfig')
-rw-r--r--drivers/thermal/intel/Kconfig117
1 files changed, 117 insertions, 0 deletions
diff --git a/drivers/thermal/intel/Kconfig b/drivers/thermal/intel/Kconfig
new file mode 100644
index 000000000..347c59bc8
--- /dev/null
+++ b/drivers/thermal/intel/Kconfig
@@ -0,0 +1,117 @@
+# SPDX-License-Identifier: GPL-2.0-only
+config INTEL_POWERCLAMP
+ tristate "Intel PowerClamp idle injection driver"
+ depends on X86
+ depends on CPU_SUP_INTEL
+ depends on CPU_IDLE
+ select POWERCAP
+ select IDLE_INJECT
+ help
+ Enable this to enable Intel PowerClamp idle injection driver. This
+ enforce idle time which results in more package C-state residency. The
+ user interface is exposed via generic thermal framework.
+
+config X86_THERMAL_VECTOR
+ def_bool y
+ depends on X86 && CPU_SUP_INTEL && X86_LOCAL_APIC
+
+config INTEL_TCC
+ bool
+ depends on X86
+
+config X86_PKG_TEMP_THERMAL
+ tristate "X86 package temperature thermal driver"
+ depends on X86_THERMAL_VECTOR && NET
+ select THERMAL_NETLINK
+ select INTEL_TCC
+ default m
+ help
+ Enable this to register CPU digital sensor for package temperature as
+ thermal zone. Each package will have its own thermal zone. There are
+ two trip points which can be set by user to get notifications via thermal
+ notification methods.
+
+config INTEL_SOC_DTS_IOSF_CORE
+ tristate
+ depends on X86 && PCI
+ select IOSF_MBI
+ select INTEL_TCC
+ help
+ This is becoming a common feature for Intel SoCs to expose the additional
+ digital temperature sensors (DTSs) using side band interface (IOSF). This
+ implements the common set of helper functions to register, get temperature
+ and get/set thresholds on DTSs.
+
+config INTEL_SOC_DTS_THERMAL
+ tristate "Intel SoCs DTS thermal driver"
+ depends on X86_64 && PCI && ACPI && NET
+ select INT340X_THERMAL
+ select INTEL_SOC_DTS_IOSF_CORE
+ help
+ Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
+ temperature sensor (DTS). These SoCs have two additional DTSs in
+ addition to DTSs on CPU cores. Each DTS will be registered as a
+ thermal zone. There are two trip points. One of the trip point can
+ be set by user mode programs to get notifications via Linux thermal
+ notification methods.The other trip is a critical trip point, which
+ was set by the driver based on the TJ MAX temperature.
+
+config INTEL_QUARK_DTS_THERMAL
+ tristate "Intel Quark DTS thermal driver"
+ depends on X86_INTEL_QUARK
+ help
+ Enable this to register Intel Quark SoC (e.g. X1000) platform digital
+ temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
+ The DTS will be registered as a thermal zone. There are two trip points:
+ hot & critical. The critical trip point default value is set by
+ underlying BIOS/Firmware.
+
+menu "ACPI INT340X thermal drivers"
+source "drivers/thermal/intel/int340x_thermal/Kconfig"
+endmenu
+
+config INTEL_BXT_PMIC_THERMAL
+ tristate "Intel Broxton PMIC thermal driver"
+ depends on X86 && INTEL_SOC_PMIC_BXTWC
+ select REGMAP
+ help
+ Select this driver for Intel Broxton PMIC with ADC channels monitoring
+ system temperature measurements and alerts.
+ This driver is used for monitoring the ADC channels of PMIC and handles
+ the alert trip point interrupts and notifies the thermal framework with
+ the trip point and temperature details of the zone.
+
+config INTEL_PCH_THERMAL
+ tristate "Intel PCH Thermal Reporting Driver"
+ depends on X86 && PCI
+ select ACPI_THERMAL_LIB if ACPI
+ help
+ Enable this to support thermal reporting on certain intel PCHs.
+ Thermal reporting device will provide temperature reading,
+ programmable trip points and other information.
+
+config INTEL_TCC_COOLING
+ tristate "Intel TCC offset cooling Driver"
+ depends on X86
+ select INTEL_TCC
+ help
+ Enable this to support system cooling by adjusting the effective TCC
+ activation temperature via the TCC Offset register, which is widely
+ supported on modern Intel platforms.
+ Note that, on different platforms, the behavior might be different
+ on how fast the setting takes effect, and how much the CPU frequency
+ is reduced.
+
+config INTEL_HFI_THERMAL
+ bool "Intel Hardware Feedback Interface"
+ depends on NET
+ depends on CPU_SUP_INTEL
+ depends on X86_THERMAL_VECTOR
+ select THERMAL_NETLINK
+ help
+ Select this option to enable the Hardware Feedback Interface. If
+ selected, hardware provides guidance to the operating system on
+ the performance and energy efficiency capabilities of each CPU.
+ These capabilities may change as a result of changes in the operating
+ conditions of the system such power and thermal limits. If selected,
+ the kernel relays updates in CPUs' capabilities to userspace.