summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/tmp102.rst
diff options
context:
space:
mode:
authorBreno Leitao <leitao@debian.org>2026-08-05 07:52:36 -0700
committerTejun Heo <tj@kernel.org>2026-08-10 11:47:20 -1000
commita5bde5d8fde8a8cb28e59a672d5ddc5b9c1e7656 (patch)
tree39f5b258386e1127d253d293194e9a2991bf3c34 /Documentation/hwmon/tmp102.rst
downloadlinux-stable-a5bde5d8fde8a8cb28e59a672d5ddc5b9c1e7656.tar.gz
linux-stable-a5bde5d8fde8a8cb28e59a672d5ddc5b9c1e7656.zip
workqueue: skip the node_nr_active update for non-unbound workqueuesgrafted
apply_wqattrs_commit() updates node_nr_active->max unconditionally. wq->node_nr_active[] is only allocated for unbound workqueues, so guard the call before per-cpu workqueues start using this path. No functional change: only unbound workqueues reach apply_wqattrs_*() today. Signed-off-by: Breno Leitao <leitao@debian.org> Signed-off-by: Tejun Heo <tj@kernel.org>
Diffstat (limited to 'Documentation/hwmon/tmp102.rst')
-rw-r--r--Documentation/hwmon/tmp102.rst65
1 files changed, 65 insertions, 0 deletions
diff --git a/Documentation/hwmon/tmp102.rst b/Documentation/hwmon/tmp102.rst
new file mode 100644
index 000000000..425a09a3c
--- /dev/null
+++ b/Documentation/hwmon/tmp102.rst
@@ -0,0 +1,65 @@
+Kernel driver tmp102
+====================
+
+Supported chips:
+
+ * Texas Instruments TMP102
+
+ Prefix: 'tmp102'
+
+ Addresses scanned: none
+
+ Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp102.html
+
+ * Texas Instruments TMP110
+
+ Prefix: 'tmp110'
+
+ Addresses scanned: none
+
+ Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp110.html
+
+ * Texas Instruments TMP113
+
+ Prefix: 'tmp113'
+
+ Addresses scanned: none
+
+ Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp113.html
+
+Author:
+
+ Steven King <sfking@fdwdc.com>
+
+Description
+-----------
+
+The Texas Instruments TMP102 implements one temperature sensor. Limits can be
+set through the Overtemperature Shutdown register and Hysteresis register. The
+sensor is accurate to 0.5 degree over the range of -25 to +85 C, and to 1.0
+degree from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The
+operating temperature has a minimum of -55 C and a maximum of +150 C.
+
+The TMP102 has a programmable update rate that can select between 8, 4, 1, and
+0.25 Hz.
+
+The TMP110 and TMP113 are software compatible with TMP102, but have different
+accuracy (maximum error) specifications. The TMP110 has an accuracy (maximum error)
+of 1.0 degree, TMP113 has an accuracy (maximum error) of 0.3 degree, while TMP102
+has an accuracy (maximum error) of 2.0 degree.
+
+sysfs-Interface
+---------------
+
+The following list includes the sysfs attributes that the driver provides, their
+permissions and a short description:
+
+=============================== ======= ===========================================
+Name Perm Description
+=============================== ======= ===========================================
+temp1_input: RO Temperature input
+temp1_label: RO Descriptive name for the sensor
+temp1_max: RW Maximum temperature
+temp1_max_hyst: RW Maximum hysteresis temperature
+update_interval RW Update conversions interval in milliseconds
+=============================== ======= ===========================================