summaryrefslogtreecommitdiffstats
path: root/Documentation/driver-api/md/raid5-ppl.rst
diff options
context:
space:
mode:
authorHaojie Li <lihaojie@kylinos.cn>2026-08-25 18:08:45 +0800
committerChun-Kuang Hu <chunkuang.hu@kernel.org>2026-09-28 23:20:55 +0000
commitbce7698e2e6565bb765bd0522337f29f5f312624 (patch)
tree0b735b7b4a27369cb4d75d9431b3ee59ce7e5bcc /Documentation/driver-api/md/raid5-ppl.rst
downloadlinux-stable-bce7698e2e6565bb765bd0522337f29f5f312624.tar.gz
linux-stable-bce7698e2e6565bb765bd0522337f29f5f312624.zip
drm/mediatek: Add missing IS_ERR check for ovl_adaptor platform devicegrafted
platform_device_register_data() can fail and return an ERR_PTR, but the return value is used without checking, leading to an invalid pointer being stored in ddp_comp[].dev and passed to component_match_add() and mtk_ddp_comp_init(), which could result in a kernel crash. Add an IS_ERR() check to jump to the error handling path on failure. Fixes: 0d9eee9118b7 ("drm/mediatek: Add drm ovl_adaptor sub driver for MT8195") Cc: stable@vger.kernel.org Signed-off-by: Haojie Li <lihaojie@kylinos.cn> Reviewed-by: CK Hu <ck.hu@mediatek.com> Link: https://patchwork.kernel.org/project/linux-mediatek/patch/20260825100845.438893-1-lihaojie@kylinos.cn/ Signed-off-by: Chun-Kuang Hu <chunkuang.hu@kernel.org>
Diffstat (limited to 'Documentation/driver-api/md/raid5-ppl.rst')
-rw-r--r--Documentation/driver-api/md/raid5-ppl.rst47
1 files changed, 47 insertions, 0 deletions
diff --git a/Documentation/driver-api/md/raid5-ppl.rst b/Documentation/driver-api/md/raid5-ppl.rst
new file mode 100644
index 000000000..357e5515b
--- /dev/null
+++ b/Documentation/driver-api/md/raid5-ppl.rst
@@ -0,0 +1,47 @@
+==================
+Partial Parity Log
+==================
+
+Partial Parity Log (PPL) is a feature available for RAID5 arrays. The issue
+addressed by PPL is that after a dirty shutdown, parity of a particular stripe
+may become inconsistent with data on other member disks. If the array is also
+in degraded state, there is no way to recalculate parity, because one of the
+disks is missing. This can lead to silent data corruption when rebuilding the
+array or using it is as degraded - data calculated from parity for array blocks
+that have not been touched by a write request during the unclean shutdown can
+be incorrect. Such condition is known as the RAID5 Write Hole. Because of
+this, md by default does not allow starting a dirty degraded array.
+
+Partial parity for a write operation is the XOR of stripe data chunks not
+modified by this write. It is just enough data needed for recovering from the
+write hole. XORing partial parity with the modified chunks produces parity for
+the stripe, consistent with its state before the write operation, regardless of
+which chunk writes have completed. If one of the not modified data disks of
+this stripe is missing, this updated parity can be used to recover its
+contents. PPL recovery is also performed when starting an array after an
+unclean shutdown and all disks are available, eliminating the need to resync
+the array. Because of this, using write-intent bitmap and PPL together is not
+supported.
+
+When handling a write request PPL writes partial parity before new data and
+parity are dispatched to disks. PPL is a distributed log - it is stored on
+array member drives in the metadata area, on the parity drive of a particular
+stripe. It does not require a dedicated journaling drive. Write performance is
+reduced by up to 30%-40% but it scales with the number of drives in the array
+and the journaling drive does not become a bottleneck or a single point of
+failure.
+
+Unlike raid5-cache, the other solution in md for closing the write hole, PPL is
+not a true journal. It does not protect from losing in-flight data, only from
+silent data corruption. If a dirty disk of a stripe is lost, no PPL recovery is
+performed for this stripe (parity is not updated). So it is possible to have
+arbitrary data in the written part of a stripe if that disk is lost. In such
+case the behavior is the same as in plain raid5.
+
+PPL is available for md version-1 metadata and external (specifically IMSM)
+metadata arrays. It can be enabled using mdadm option --consistency-policy=ppl.
+
+There is a limitation of maximum 64 disks in the array for PPL. It allows to
+keep data structures and implementation simple. RAID5 arrays with so many disks
+are not likely due to high risk of multiple disks failure. Such restriction
+should not be a real life limitation.