summaryrefslogtreecommitdiffstats
path: root/Documentation/admin-guide/perf
diff options
context:
space:
mode:
authorAdrian Betschart <adrian.betschart@cinemaone.ch>2026-09-11 17:13:14 +0200
committerAlex Deucher <alexander.deucher@amd.com>2026-10-01 17:18:05 -0400
commit106b4a2a78b2a2f14885604891957b84bba502db (patch)
tree5d40eef2428fb1a4791ab46a4b19091a5910eac2 /Documentation/admin-guide/perf
downloadlinux-stable-106b4a2a78b2a2f14885604891957b84bba502db.tar.gz
linux-stable-106b4a2a78b2a2f14885604891957b84bba502db.zip
drm/amd/display: Try RGB before YCbCr 4:4:4 in stream validationgrafted
amdgpu_dm_create_validate_stream_for_sink() walks encoding_order[] and uses the first encoding that validates. YCbCr 4:4:4 is listed before RGB, so an HDMI sink that advertises 4:4:4 gets YCbCr 4:4:4 whenever the "color format" property is left at AUTO, even though RGB fits the same link. That contradicts the documented AUTO behaviour for HDMI in enum drm_connector_color_format (RGB, falling back to YCbCr 4:2:0 only when the bandwidth is not available or the mode is 4:2:0-only), which the amdgpu implementation of the property also describes. It also leaves the "Broadcast RGB" property without effect on such sinks, since the quantization range it selects only applies to RGB output. Try RGB first. The mask still holds every encoding the sink supports, so a mode that cannot carry RGB falls back exactly as before. For reference, v7.2 picked RGB here unless YCbCr 4:4:4 was forced through debugfs, while earlier kernels picked YCbCr 4:4:4 for any HDMI sink that advertised it. Fixes: 0b0ff65d3ca1 ("drm/amd/display: Refactor stream validation") Suggested-by: Adolfo Rodrigues <adolfotregosa@gmail.com> Assisted-by: Claude Code:claude-fable-5-1 Signed-off-by: Adrian Betschart <adrian.betschart@cinemaone.ch> Reviewed-by: Fangzhi Zuo <jerry.zuo@amd.com> Tested-by: Adolfo Rodrigues <adolfotregosa@gmail.com> Tested-by: Daniel Wheeler <daniel.wheeler@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com> (cherry picked from commit 7de432bc753133764dc40d37f9388da56de251e7)
Diffstat (limited to 'Documentation/admin-guide/perf')
-rw-r--r--Documentation/admin-guide/perf/alibaba_pmu.rst105
-rw-r--r--Documentation/admin-guide/perf/ampere_cspmu.rst29
-rw-r--r--Documentation/admin-guide/perf/arm-ccn.rst61
-rw-r--r--Documentation/admin-guide/perf/arm-cmn.rst65
-rw-r--r--Documentation/admin-guide/perf/arm-ni.rst17
-rw-r--r--Documentation/admin-guide/perf/arm_dsu_pmu.rst29
-rw-r--r--Documentation/admin-guide/perf/cxl.rst68
-rw-r--r--Documentation/admin-guide/perf/dwc_pcie_pmu.rst94
-rw-r--r--Documentation/admin-guide/perf/fujitsu_uncore_pmu.rst115
-rw-r--r--Documentation/admin-guide/perf/hisi-pcie-pmu.rst148
-rw-r--r--Documentation/admin-guide/perf/hisi-pmu.rst177
-rw-r--r--Documentation/admin-guide/perf/hns3-pmu.rst136
-rw-r--r--Documentation/admin-guide/perf/imx-ddr.rst100
-rw-r--r--Documentation/admin-guide/perf/index.rst33
-rw-r--r--Documentation/admin-guide/perf/meson-ddr-pmu.rst70
-rw-r--r--Documentation/admin-guide/perf/mrvl-odyssey-ddr-pmu.rst80
-rw-r--r--Documentation/admin-guide/perf/mrvl-odyssey-tad-pmu.rst37
-rw-r--r--Documentation/admin-guide/perf/mrvl-pem-pmu.rst56
-rw-r--r--Documentation/admin-guide/perf/nvidia-tegra241-pmu.rst333
-rw-r--r--Documentation/admin-guide/perf/nvidia-tegra410-pmu.rst522
-rw-r--r--Documentation/admin-guide/perf/qcom_l2_pmu.rst39
-rw-r--r--Documentation/admin-guide/perf/qcom_l3_pmu.rst26
-rw-r--r--Documentation/admin-guide/perf/starfive_starlink_pmu.rst46
-rw-r--r--Documentation/admin-guide/perf/thunderx2-pmu.rst44
-rw-r--r--Documentation/admin-guide/perf/xgene-pmu.rst49
25 files changed, 2479 insertions, 0 deletions
diff --git a/Documentation/admin-guide/perf/alibaba_pmu.rst b/Documentation/admin-guide/perf/alibaba_pmu.rst
new file mode 100644
index 000000000..7d8400239
--- /dev/null
+++ b/Documentation/admin-guide/perf/alibaba_pmu.rst
@@ -0,0 +1,105 @@
+=============================================================
+Alibaba's T-Head SoC Uncore Performance Monitoring Unit (PMU)
+=============================================================
+
+The Yitian 710, custom-built by Alibaba Group's chip development business,
+T-Head, implements uncore PMU for performance and functional debugging to
+facilitate system maintenance.
+
+DDR Sub-System Driveway (DRW) PMU Driver
+=========================================
+
+Yitian 710 employs eight DDR5/4 channels, four on each die. Each DDR5 channel
+is independent of others to service system memory requests. And one DDR5
+channel is split into two independent sub-channels. The DDR Sub-System Driveway
+implements separate PMUs for each sub-channel to monitor various performance
+metrics.
+
+The Driveway PMU devices are named as ali_drw_<sys_base_addr> with perf.
+For example, ali_drw_21000 and ali_drw_21080 are two PMU devices for two
+sub-channels of the same channel in die 0. And the PMU device of die 1 is
+prefixed with ali_drw_400XXXXX, e.g. ali_drw_40021000.
+
+Each sub-channel has 36 PMU counters in total, which is classified into
+four groups:
+
+- Group 0: PMU Cycle Counter. This group has one pair of counters
+ pmu_cycle_cnt_low and pmu_cycle_cnt_high, that is used as the cycle count
+ based on DDRC core clock.
+
+- Group 1: PMU Bandwidth Counters. This group has 8 counters that are used
+ to count the total access number of either the eight bank groups in a
+ selected rank, or four ranks separately in the first 4 counters. The base
+ transfer unit is 64B.
+
+- Group 2: PMU Retry Counters. This group has 10 counters, that intend to
+ count the total retry number of each type of uncorrectable error.
+
+- Group 3: PMU Common Counters. This group has 16 counters, that are used
+ to count the common events.
+
+For now, the Driveway PMU driver only uses counters in group 0 and group 3.
+
+The DDR Controller (DDRCTL) and DDR PHY combine to create a complete solution
+for connecting an SoC application bus to DDR memory devices. The DDRCTL
+receives transactions Host Interface (HIF) which is custom-defined by Synopsys.
+These transactions are queued internally and scheduled for access while
+satisfying the SDRAM protocol timing requirements, transaction priorities, and
+dependencies between the transactions. The DDRCTL in turn issues commands on
+the DDR PHY Interface (DFI) to the PHY module, which launches and captures data
+to and from the SDRAM. The driveway PMUs have hardware logic to gather
+statistics and performance logging signals on HIF, DFI, etc.
+
+By counting the READ, WRITE and RMW commands sent to the DDRC through the HIF
+interface, we could calculate the bandwidth. Example usage of counting memory
+data bandwidth::
+
+ perf stat \
+ -e ali_drw_21000/hif_wr/ \
+ -e ali_drw_21000/hif_rd/ \
+ -e ali_drw_21000/hif_rmw/ \
+ -e ali_drw_21000/cycle/ \
+ -e ali_drw_21080/hif_wr/ \
+ -e ali_drw_21080/hif_rd/ \
+ -e ali_drw_21080/hif_rmw/ \
+ -e ali_drw_21080/cycle/ \
+ -e ali_drw_23000/hif_wr/ \
+ -e ali_drw_23000/hif_rd/ \
+ -e ali_drw_23000/hif_rmw/ \
+ -e ali_drw_23000/cycle/ \
+ -e ali_drw_23080/hif_wr/ \
+ -e ali_drw_23080/hif_rd/ \
+ -e ali_drw_23080/hif_rmw/ \
+ -e ali_drw_23080/cycle/ \
+ -e ali_drw_25000/hif_wr/ \
+ -e ali_drw_25000/hif_rd/ \
+ -e ali_drw_25000/hif_rmw/ \
+ -e ali_drw_25000/cycle/ \
+ -e ali_drw_25080/hif_wr/ \
+ -e ali_drw_25080/hif_rd/ \
+ -e ali_drw_25080/hif_rmw/ \
+ -e ali_drw_25080/cycle/ \
+ -e ali_drw_27000/hif_wr/ \
+ -e ali_drw_27000/hif_rd/ \
+ -e ali_drw_27000/hif_rmw/ \
+ -e ali_drw_27000/cycle/ \
+ -e ali_drw_27080/hif_wr/ \
+ -e ali_drw_27080/hif_rd/ \
+ -e ali_drw_27080/hif_rmw/ \
+ -e ali_drw_27080/cycle/ -- sleep 10
+
+Example usage of counting all memory read/write bandwidth by metric::
+
+ perf stat -M ddr_read_bandwidth.all -- sleep 10
+ perf stat -M ddr_write_bandwidth.all -- sleep 10
+
+The average DRAM bandwidth can be calculated as follows:
+
+- Read Bandwidth = perf_hif_rd * DDRC_WIDTH * DDRC_Freq / DDRC_Cycle
+- Write Bandwidth = (perf_hif_wr + perf_hif_rmw) * DDRC_WIDTH * DDRC_Freq / DDRC_Cycle
+
+Here, DDRC_WIDTH = 64 bytes.
+
+The current driver does not support sampling. So "perf record" is
+unsupported. Also attach to a task is unsupported as the events are all
+uncore.
diff --git a/Documentation/admin-guide/perf/ampere_cspmu.rst b/Documentation/admin-guide/perf/ampere_cspmu.rst
new file mode 100644
index 000000000..94f93f5ae
--- /dev/null
+++ b/Documentation/admin-guide/perf/ampere_cspmu.rst
@@ -0,0 +1,29 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+============================================
+Ampere SoC Performance Monitoring Unit (PMU)
+============================================
+
+Ampere SoC PMU is a generic PMU IP that follows Arm CoreSight PMU architecture.
+Therefore, the driver is implemented as a submodule of arm_cspmu driver. At the
+first phase it's used for counting MCU events on AmpereOne.
+
+
+MCU PMU events
+--------------
+
+The PMU driver supports setting filters for "rank", "bank", and "threshold".
+Note, that the filters are per PMU instance rather than per event.
+
+
+Example for perf tool use::
+
+ / # perf list ampere
+
+ ampere_mcu_pmu_0/act_sent/ [Kernel PMU event]
+ <...>
+ ampere_mcu_pmu_1/rd_sent/ [Kernel PMU event]
+ <...>
+
+ / # perf stat -a -e ampere_mcu_pmu_0/act_sent,bank=5,rank=3,threshold=2/,ampere_mcu_pmu_1/rd_sent/ \
+ sleep 1
diff --git a/Documentation/admin-guide/perf/arm-ccn.rst b/Documentation/admin-guide/perf/arm-ccn.rst
new file mode 100644
index 000000000..f62f7fe50
--- /dev/null
+++ b/Documentation/admin-guide/perf/arm-ccn.rst
@@ -0,0 +1,61 @@
+==========================
+ARM Cache Coherent Network
+==========================
+
+CCN-504 is a ring-bus interconnect consisting of 11 crosspoints
+(XPs), with each crosspoint supporting up to two device ports,
+so nodes (devices) 0 and 1 are connected to crosspoint 0,
+nodes 2 and 3 to crosspoint 1 etc.
+
+PMU (perf) driver
+-----------------
+
+The CCN driver registers a perf PMU driver, which provides
+description of available events and configuration options
+in sysfs, see /sys/bus/event_source/devices/ccn*.
+
+The "format" directory describes format of the config, config1
+and config2 fields of the perf_event_attr structure. The "events"
+directory provides configuration templates for all documented
+events, that can be used with perf tool. For example "xp_valid_flit"
+is an equivalent of "type=0x8,event=0x4". Other parameters must be
+explicitly specified.
+
+For events originating from device, "node" defines its index.
+
+Crosspoint PMU events require "xp" (index), "bus" (bus number)
+and "vc" (virtual channel ID).
+
+Crosspoint watchpoint-based events (special "event" value 0xfe)
+require "xp" and "vc" as above plus "port" (device port index),
+"dir" (transmit/receive direction), comparator values ("cmp_l"
+and "cmp_h") and "mask", being index of the comparator mask.
+
+Masks are defined separately from the event description
+(due to limited number of the config values) in the "cmp_mask"
+directory, with first 8 configurable by user and additional
+4 hardcoded for the most frequent use cases.
+
+Cycle counter is described by a "type" value 0xff and does
+not require any other settings.
+
+The driver also provides a "cpumask" sysfs attribute, which contains
+a single CPU ID, of the processor which will be used to handle all
+the CCN PMU events. It is recommended that the user space tools
+request the events on this processor (if not, the perf_event->cpu value
+will be overwritten anyway). In case of this processor being offlined,
+the events are migrated to another one and the attribute is updated.
+
+Example of perf tool use::
+
+ / # perf list | grep ccn
+ ccn/cycles/ [Kernel PMU event]
+ <...>
+ ccn/xp_valid_flit,xp=?,port=?,vc=?,dir=?/ [Kernel PMU event]
+ <...>
+
+ / # perf stat -a -e ccn/cycles/,ccn/xp_valid_flit,xp=1,port=0,vc=1,dir=1/ \
+ sleep 1
+
+The driver does not support sampling, therefore "perf record" will
+not work. Per-task (without "-a") perf sessions are not supported.
diff --git a/Documentation/admin-guide/perf/arm-cmn.rst b/Documentation/admin-guide/perf/arm-cmn.rst
new file mode 100644
index 000000000..796e25b70
--- /dev/null
+++ b/Documentation/admin-guide/perf/arm-cmn.rst
@@ -0,0 +1,65 @@
+=============================
+Arm Coherent Mesh Network PMU
+=============================
+
+CMN-600 is a configurable mesh interconnect consisting of a rectangular
+grid of crosspoints (XPs), with each crosspoint supporting up to two
+device ports to which various AMBA CHI agents are attached.
+
+CMN implements a distributed PMU design as part of its debug and trace
+functionality. This consists of a local monitor (DTM) at every XP, which
+counts up to 4 event signals from the connected device nodes and/or the
+XP itself. Overflow from these local counters is accumulated in up to 8
+global counters implemented by the main controller (DTC), which provides
+overall PMU control and interrupts for global counter overflow.
+
+PMU events
+----------
+
+The PMU driver registers a single PMU device for the whole interconnect,
+see /sys/bus/event_source/devices/arm_cmn_0. Multi-chip systems may link
+more than one CMN together via external CCIX links - in this situation,
+each mesh counts its own events entirely independently, and additional
+PMU devices will be named arm_cmn_{1..n}.
+
+Most events are specified in a format based directly on the TRM
+definitions - "type" selects the respective node type, and "eventid" the
+event number. Some events require an additional occupancy ID, which is
+specified by "occupid".
+
+* Since RN-D nodes do not have any distinct events from RN-I nodes, they
+ are treated as the same type (0xa), and the common event templates are
+ named "rnid_*".
+
+* The cycle counter is treated as a synthetic event belonging to the DTC
+ node ("type" == 0x3, "eventid" is ignored).
+
+* XP events also encode the port and channel in the "eventid" field, to
+ match the underlying pmu_event0_id encoding for the pmu_event_sel
+ register. The event templates are named with prefixes to cover all
+ permutations.
+
+By default each event provides an aggregate count over all nodes of the
+given type. To target a specific node, "bynodeid" must be set to 1 and
+"nodeid" to the appropriate value derived from the CMN configuration
+(as defined in the "Node ID Mapping" section of the TRM).
+
+Watchpoints
+-----------
+
+The PMU can also count watchpoint events to monitor specific flit
+traffic. Watchpoints are treated as a synthetic event type, and like PMU
+events can be global or targeted with a particular XP's "nodeid" value.
+Since the watchpoint direction is otherwise implicit in the underlying
+register selection, separate events are provided for flit uploads and
+downloads.
+
+The flit match value and mask are passed in config1 and config2 ("val"
+and "mask" respectively). "wp_dev_sel", "wp_chn_sel", "wp_grp" and
+"wp_exclusive" are specified per the TRM definitions for dtm_wp_config0.
+Where a watchpoint needs to match fields from both match groups on the
+REQ or SNP channel, it can be specified as two events - one for each
+group - with the same nonzero "combine" value. The count for such a
+pair of combined events will be attributed to the primary match.
+Watchpoint events with a "combine" value of 0 are considered independent
+and will count individually.
diff --git a/Documentation/admin-guide/perf/arm-ni.rst b/Documentation/admin-guide/perf/arm-ni.rst
new file mode 100644
index 000000000..d26a8f697
--- /dev/null
+++ b/Documentation/admin-guide/perf/arm-ni.rst
@@ -0,0 +1,17 @@
+====================================
+Arm Network-on Chip Interconnect PMU
+====================================
+
+NI-700 and friends implement a distinct PMU for each clock domain within the
+interconnect. Correspondingly, the driver exposes multiple PMU devices named
+arm_ni_<x>_cd_<y>, where <x> is an (arbitrary) instance identifier and <y> is
+the clock domain ID within that particular instance. If multiple NI instances
+exist within a system, the PMU devices can be correlated with the underlying
+hardware instance via sysfs parentage.
+
+Each PMU exposes base event aliases for the interface types present in its clock
+domain. These require qualifying with the "eventid" and "nodeid" parameters
+to specify the event code to count and the interface at which to count it
+(per the configured hardware ID as reflected in the xxNI_NODE_INFO register).
+The exception is the "cycles" alias for the PMU cycle counter, which is encoded
+with the PMU node type and needs no further qualification.
diff --git a/Documentation/admin-guide/perf/arm_dsu_pmu.rst b/Documentation/admin-guide/perf/arm_dsu_pmu.rst
new file mode 100644
index 000000000..7fd34db75
--- /dev/null
+++ b/Documentation/admin-guide/perf/arm_dsu_pmu.rst
@@ -0,0 +1,29 @@
+==================================
+ARM DynamIQ Shared Unit (DSU) PMU
+==================================
+
+ARM DynamIQ Shared Unit integrates one or more cores with an L3 memory system,
+control logic and external interfaces to form a multicore cluster. The PMU
+allows counting the various events related to the L3 cache, Snoop Control Unit
+etc, using 32bit independent counters. It also provides a 64bit cycle counter.
+
+The PMU can only be accessed via CPU system registers and are common to the
+cores connected to the same DSU. Like most of the other uncore PMUs, DSU
+PMU doesn't support process specific events and cannot be used in sampling mode.
+
+The DSU provides a bitmap for a subset of implemented events via hardware
+registers. There is no way for the driver to determine if the other events
+are available or not. Hence the driver exposes only those events advertised
+by the DSU, in "events" directory under::
+
+ /sys/bus/event_sources/devices/arm_dsu_<N>/
+
+The user should refer to the TRM of the product to figure out the supported events
+and use the raw event code for the unlisted events.
+
+The driver also exposes the CPUs connected to the DSU instance in "associated_cpus".
+
+
+e.g usage::
+
+ perf stat -a -e arm_dsu_0/cycles/
diff --git a/Documentation/admin-guide/perf/cxl.rst b/Documentation/admin-guide/perf/cxl.rst
new file mode 100644
index 000000000..9233ea0d0
--- /dev/null
+++ b/Documentation/admin-guide/perf/cxl.rst
@@ -0,0 +1,68 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+======================================
+CXL Performance Monitoring Unit (CPMU)
+======================================
+
+The CXL rev 3.0 specification provides a definition of CXL Performance
+Monitoring Unit in section 13.2: Performance Monitoring.
+
+CXL components (e.g. Root Port, Switch Upstream Port, End Point) may have
+any number of CPMU instances. CPMU capabilities are fully discoverable from
+the devices. The specification provides event definitions for all CXL protocol
+message types and a set of additional events for things commonly counted on
+CXL devices (e.g. DRAM events).
+
+CPMU driver
+===========
+
+The CPMU driver registers a perf PMU with the name pmu_mem<X>.<Y> on the CXL bus
+representing the Yth CPMU for memX.
+
+ /sys/bus/cxl/device/pmu_mem<X>.<Y>
+
+The associated PMU is registered as
+
+ /sys/bus/event_sources/devices/cxl_pmu_mem<X>.<Y>
+
+In common with other CXL bus devices, the id has no specific meaning and the
+relationship to specific CXL device should be established via the device parent
+of the device on the CXL bus.
+
+PMU driver provides description of available events and filter options in sysfs.
+
+The "format" directory describes all formats of the config (event vendor id,
+group id and mask) config1 (threshold, filter enables) and config2 (filter
+parameters) fields of the perf_event_attr structure. The "events" directory
+describes all documented events show in perf list.
+
+The events shown in perf list are the most fine grained events with a single
+bit of the event mask set. More general events may be enable by setting
+multiple mask bits in config. For example, all Device to Host Read Requests
+may be captured on a single counter by setting the bits for all of
+
+* d2h_req_rdcurr
+* d2h_req_rdown
+* d2h_req_rdshared
+* d2h_req_rdany
+* d2h_req_rdownnodata
+
+Example of usage::
+
+ $#perf list
+ cxl_pmu_mem0.0/clock_ticks/ [Kernel PMU event]
+ cxl_pmu_mem0.0/d2h_req_rdshared/ [Kernel PMU event]
+ cxl_pmu_mem0.0/h2d_req_snpcur/ [Kernel PMU event]
+ cxl_pmu_mem0.0/h2d_req_snpdata/ [Kernel PMU event]
+ cxl_pmu_mem0.0/h2d_req_snpinv/ [Kernel PMU event]
+ -----------------------------------------------------------
+
+ $# perf stat -a -e cxl_pmu_mem0.0/clock_ticks/ -e cxl_pmu_mem0.0/d2h_req_rdshared/
+
+Vendor specific events may also be available and if so can be used via
+
+ $# perf stat -a -e cxl_pmu_mem0.0/vid=VID,gid=GID,mask=MASK/
+
+The driver does not support sampling so "perf record" is unsupported.
+It only supports system-wide counting so attaching to a task is
+unsupported.
diff --git a/Documentation/admin-guide/perf/dwc_pcie_pmu.rst b/Documentation/admin-guide/perf/dwc_pcie_pmu.rst
new file mode 100644
index 000000000..167f9281f
--- /dev/null
+++ b/Documentation/admin-guide/perf/dwc_pcie_pmu.rst
@@ -0,0 +1,94 @@
+======================================================================
+Synopsys DesignWare Cores (DWC) PCIe Performance Monitoring Unit (PMU)
+======================================================================
+
+DesignWare Cores (DWC) PCIe PMU
+===============================
+
+The PMU is a PCIe configuration space register block provided by each PCIe Root
+Port in a Vendor-Specific Extended Capability named RAS D.E.S (Debug, Error
+injection, and Statistics).
+
+As the name indicates, the RAS DES capability supports system level
+debugging, AER error injection, and collection of statistics. To facilitate
+collection of statistics, Synopsys DesignWare Cores PCIe controller
+provides the following two features:
+
+- one 64-bit counter for Time Based Analysis (RX/TX data throughput and
+ time spent in each low-power LTSSM state) and
+- one 32-bit counter per event for Event Counting (error and non-error
+ events for a specified lane)
+
+Note: There is no interrupt for counter overflow.
+
+Time Based Analysis
+-------------------
+
+Using this feature you can obtain information regarding RX/TX data
+throughput and time spent in each low-power LTSSM state by the controller.
+The PMU measures data in two categories:
+
+- Group#0: Percentage of time the controller stays in LTSSM states.
+- Group#1: Amount of data processed (Units of 16 bytes).
+
+Lane Event counters
+-------------------
+
+Using this feature you can obtain Error and Non-Error information in
+specific lane by the controller. The PMU event is selected by all of:
+
+- Group i
+- Event j within the Group i
+- Lane k
+
+Some of the events only exist for specific configurations.
+
+DesignWare Cores (DWC) PCIe PMU Driver
+=======================================
+
+This driver adds PMU devices for each PCIe Root Port named based on the SBDF of
+the Root Port. For example,
+
+ 0001:30:03.0 PCI bridge: Device 1ded:8000 (rev 01)
+
+the PMU device name for this Root Port is dwc_rootport_13018.
+
+The DWC PCIe PMU driver registers a perf PMU driver, which provides
+description of available events and configuration options in sysfs, see
+/sys/bus/event_source/devices/dwc_rootport_{sbdf}.
+
+The "format" directory describes format of the config fields of the
+perf_event_attr structure. The "events" directory provides configuration
+templates for all documented events. For example,
+"rx_pcie_tlp_data_payload" is an equivalent of "eventid=0x21,type=0x0".
+
+The "perf list" command shall list the available events from sysfs, e.g.::
+
+ $# perf list | grep dwc_rootport
+ <...>
+ dwc_rootport_13018/Rx_PCIe_TLP_Data_Payload/ [Kernel PMU event]
+ <...>
+ dwc_rootport_13018/rx_memory_read,lane=?/ [Kernel PMU event]
+
+Time Based Analysis Event Usage
+-------------------------------
+
+Example usage of counting PCIe RX TLP data payload (Units of bytes)::
+
+ $# perf stat -a -e dwc_rootport_13018/Rx_PCIe_TLP_Data_Payload/
+
+The average RX/TX bandwidth can be calculated using the following formula:
+
+ PCIe RX Bandwidth = rx_pcie_tlp_data_payload / Measure_Time_Window
+ PCIe TX Bandwidth = tx_pcie_tlp_data_payload / Measure_Time_Window
+
+Lane Event Usage
+-------------------------------
+
+Each lane has the same event set and to avoid generating a list of hundreds
+of events, the user need to specify the lane ID explicitly, e.g.::
+
+ $# perf stat -a -e dwc_rootport_13018/rx_memory_read,lane=4/
+
+The driver does not support sampling, therefore "perf record" will not
+work. Per-task (without "-a") perf sessions are not supported.
diff --git a/Documentation/admin-guide/perf/fujitsu_uncore_pmu.rst b/Documentation/admin-guide/perf/fujitsu_uncore_pmu.rst
new file mode 100644
index 000000000..2ec0249e3
--- /dev/null
+++ b/Documentation/admin-guide/perf/fujitsu_uncore_pmu.rst
@@ -0,0 +1,115 @@
+.. SPDX-License-Identifier: GPL-2.0-only
+
+================================================
+Fujitsu Uncore Performance Monitoring Unit (PMU)
+================================================
+
+This driver supports the Uncore MAC PMUs and the Uncore PCI PMUs found
+in Fujitsu chips.
+Each MAC PMU on these chips is exposed as a uncore perf PMU with device name
+mac_iod<iod>_mac<mac>_ch<ch>.
+And each PCI PMU on these chips is exposed as a uncore perf PMU with device name
+pci_iod<iod>_pci<pci>.
+
+The driver provides a description of its available events and configuration
+options in sysfs, see /sys/bus/event_sources/devices/mac_iod<iod>_mac<mac>_ch<ch>/
+and /sys/bus/event_sources/devices/pci_iod<iod>_pci<pci>/.
+This driver exports:
+
+- formats, used by perf user space and other tools to configure events
+- events, used by perf user space and other tools to create events
+ symbolically, e.g.::
+
+ perf stat -a -e mac_iod0_mac0_ch0/event=0x21/ ls
+ perf stat -a -e pci_iod0_pci0/event=0x24/ ls
+
+- cpumask, used by perf user space and other tools to know on which CPUs
+ to open the events
+
+This driver supports the following events for MAC:
+
+- cycles
+ This event counts MAC cycles at MAC frequency.
+- read-count
+ This event counts the number of read requests to MAC.
+- read-count-request
+ This event counts the number of read requests including retry to MAC.
+- read-count-return
+ This event counts the number of responses to read requests to MAC.
+- read-count-request-pftgt
+ This event counts the number of read requests including retry with PFTGT
+ flag.
+- read-count-request-normal
+ This event counts the number of read requests including retry without PFTGT
+ flag.
+- read-count-return-pftgt-hit
+ This event counts the number of responses to read requests which hit the
+ PFTGT buffer.
+- read-count-return-pftgt-miss
+ This event counts the number of responses to read requests which miss the
+ PFTGT buffer.
+- read-wait
+ This event counts outstanding read requests issued by DDR memory controller
+ per cycle.
+- write-count
+ This event counts the number of write requests to MAC (including zero write,
+ full write, partial write, write cancel).
+- write-count-write
+ This event counts the number of full write requests to MAC (not including
+ zero write).
+- write-count-pwrite
+ This event counts the number of partial write requests to MAC.
+- memory-read-count
+ This event counts the number of read requests from MAC to memory.
+- memory-write-count
+ This event counts the number of full write requests from MAC to memory.
+- memory-pwrite-count
+ This event counts the number of partial write requests from MAC to memory.
+- ea-mac
+ This event counts energy consumption of MAC.
+- ea-memory
+ This event counts energy consumption of memory.
+- ea-memory-mac-write
+ This event counts the number of write requests from MAC to memory.
+- ea-ha
+ This event counts energy consumption of HA.
+
+ 'ea' is the abbreviation for 'Energy Analyzer'.
+
+Examples for use with perf::
+
+ perf stat -e mac_iod0_mac0_ch0/ea-mac/ ls
+
+And, this driver supports the following events for PCI:
+
+- pci-port0-cycles
+ This event counts PCI cycles at PCI frequency in port0.
+- pci-port0-read-count
+ This event counts read transactions for data transfer in port0.
+- pci-port0-read-count-bus
+ This event counts read transactions for bus usage in port0.
+- pci-port0-write-count
+ This event counts write transactions for data transfer in port0.
+- pci-port0-write-count-bus
+ This event counts write transactions for bus usage in port0.
+- pci-port1-cycles
+ This event counts PCI cycles at PCI frequency in port1.
+- pci-port1-read-count
+ This event counts read transactions for data transfer in port1.
+- pci-port1-read-count-bus
+ This event counts read transactions for bus usage in port1.
+- pci-port1-write-count
+ This event counts write transactions for data transfer in port1.
+- pci-port1-write-count-bus
+ This event counts write transactions for bus usage in port1.
+- ea-pci
+ This event counts energy consumption of PCI.
+
+ 'ea' is the abbreviation for 'Energy Analyzer'.
+
+Examples for use with perf::
+
+ perf stat -e pci_iod0_pci0/ea-pci/ ls
+
+Given that these are uncore PMUs the driver does not support sampling, therefore
+"perf record" will not work. Per-task perf sessions are not supported.
diff --git a/Documentation/admin-guide/perf/hisi-pcie-pmu.rst b/Documentation/admin-guide/perf/hisi-pcie-pmu.rst
new file mode 100644
index 000000000..083ca50de
--- /dev/null
+++ b/Documentation/admin-guide/perf/hisi-pcie-pmu.rst
@@ -0,0 +1,148 @@
+================================================
+HiSilicon PCIe Performance Monitoring Unit (PMU)
+================================================
+
+On Hip09, HiSilicon PCIe Performance Monitoring Unit (PMU) could monitor
+bandwidth, latency, bus utilization and buffer occupancy data of PCIe.
+
+Each PCIe Core has a PMU to monitor multi Root Ports of this PCIe Core and
+all Endpoints downstream these Root Ports.
+
+
+HiSilicon PCIe PMU driver
+=========================
+
+The PCIe PMU driver registers a perf PMU with the name of its sicl-id and PCIe
+Core id.::
+
+ /sys/bus/event_source/hisi_pcie<sicl>_core<core>
+
+PMU driver provides description of available events and filter options in sysfs,
+see /sys/bus/event_source/devices/hisi_pcie<sicl>_core<core>.
+
+The "format" directory describes all formats of the config (events) and config1
+(filter options) fields of the perf_event_attr structure. The "events" directory
+describes all documented events shown in perf list.
+
+The "identifier" sysfs file allows users to identify the version of the
+PMU hardware device.
+
+The "bus" sysfs file allows users to get the bus number of Root Ports
+monitored by PMU. Furthermore users can get the Root Ports range in
+[bdf_min, bdf_max] from "bdf_min" and "bdf_max" sysfs attributes
+respectively.
+
+Example usage of perf::
+
+ $# perf list
+ hisi_pcie0_core0/rx_mwr_latency/ [kernel PMU event]
+ hisi_pcie0_core0/rx_mwr_cnt/ [kernel PMU event]
+ ------------------------------------------
+
+ $# perf stat -e hisi_pcie0_core0/rx_mwr_latency,port=0xffff/
+ $# perf stat -e hisi_pcie0_core0/rx_mwr_cnt,port=0xffff/
+
+The related events usually used to calculate the bandwidth, latency or others.
+They need to start and end counting at the same time, therefore related events
+are best used in the same event group to get the expected value. There are two
+ways to know if they are related events:
+
+a) By event name, such as the latency events "xxx_latency, xxx_cnt" or
+ bandwidth events "xxx_flux, xxx_time".
+b) By event type, such as "event=0xXXXX, event=0x1XXXX".
+
+Example usage of perf group::
+
+ $# perf stat -e "{hisi_pcie0_core0/rx_mwr_latency,port=0xffff/,hisi_pcie0_core0/rx_mwr_cnt,port=0xffff/}"
+
+The current driver does not support sampling. So "perf record" is unsupported.
+Also attach to a task is unsupported for PCIe PMU.
+
+Filter options
+--------------
+
+1. Target filter
+
+ PMU could only monitor the performance of traffic downstream target Root
+ Ports or downstream target Endpoint. PCIe PMU driver support "port" and
+ "bdf" interfaces for users.
+ Please notice that, one of these two interfaces must be set, and these two
+ interfaces aren't supported at the same time. If they are both set, only
+ "port" filter is valid.
+ If "port" filter not being set or is set explicitly to zero (default), the
+ "bdf" filter will be in effect, because "bdf=0" meaning 0000:000:00.0.
+
+ - port
+
+ "port" filter can be used in all PCIe PMU events, target Root Port can be
+ selected by configuring the 16-bits-bitmap "port". Multi ports can be
+ selected for AP-layer-events, and only one port can be selected for
+ TL/DL-layer-events.
+
+ For example, if target Root Port is 0000:00:00.0 (x8 lanes), bit0 of
+ bitmap should be set, port=0x1; if target Root Port is 0000:00:04.0 (x4
+ lanes), bit8 is set, port=0x100; if these two Root Ports are both
+ monitored, port=0x101.
+
+ Example usage of perf::
+
+ $# perf stat -e hisi_pcie0_core0/rx_mwr_latency,port=0x1/ sleep 5
+
+ - bdf
+
+ "bdf" filter can only be used in bandwidth events, target Endpoint is
+ selected by configuring BDF to "bdf". Counter only counts the bandwidth of
+ message requested by target Endpoint.
+
+ For example, "bdf=0x3900" means BDF of target Endpoint is 0000:39:00.0.
+
+ Example usage of perf::
+
+ $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,bdf=0x3900/ sleep 5
+
+2. Trigger filter
+
+ Event statistics start when the first time TLP length is greater/smaller
+ than trigger condition. You can set the trigger condition by writing
+ "trig_len", and set the trigger mode by writing "trig_mode". This filter can
+ only be used in bandwidth events.
+
+ For example, "trig_len=4" means trigger condition is 2^4 DW, "trig_mode=0"
+ means statistics start when TLP length > trigger condition, "trig_mode=1"
+ means start when TLP length < condition.
+
+ Example usage of perf::
+
+ $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,port=0xffff,trig_len=0x4,trig_mode=1/ sleep 5
+
+3. Threshold filter
+
+ Counter counts when TLP length within the specified range. You can set the
+ threshold by writing "thr_len", and set the threshold mode by writing
+ "thr_mode". This filter can only be used in bandwidth events.
+
+ For example, "thr_len=4" means threshold is 2^4 DW, "thr_mode=0" means
+ counter counts when TLP length >= threshold, and "thr_mode=1" means counts
+ when TLP length < threshold.
+
+ Example usage of perf::
+
+ $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,port=0xffff,thr_len=0x4,thr_mode=1/ sleep 5
+
+4. TLP Length filter
+
+ When counting bandwidth, the data can be composed of certain parts of TLP
+ packets. You can specify it through "len_mode":
+
+ - 2'b00: Reserved (Do not use this since the behaviour is undefined)
+ - 2'b01: Bandwidth of TLP payloads
+ - 2'b10: Bandwidth of TLP headers
+ - 2'b11: Bandwidth of both TLP payloads and headers
+
+ For example, "len_mode=2" means only counting the bandwidth of TLP headers
+ and "len_mode=3" means the final bandwidth data is composed of both TLP
+ headers and payloads. Default value if not specified is 2'b11.
+
+ Example usage of perf::
+
+ $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,port=0xffff,len_mode=0x1/ sleep 5
diff --git a/Documentation/admin-guide/perf/hisi-pmu.rst b/Documentation/admin-guide/perf/hisi-pmu.rst
new file mode 100644
index 000000000..d56b2d690
--- /dev/null
+++ b/Documentation/admin-guide/perf/hisi-pmu.rst
@@ -0,0 +1,177 @@
+======================================================
+HiSilicon SoC uncore Performance Monitoring Unit (PMU)
+======================================================
+
+The HiSilicon SoC chip includes various independent system device PMUs
+such as L3 cache (L3C), Hydra Home Agent (HHA) and DDRC. These PMUs are
+independent and have hardware logic to gather statistics and performance
+information.
+
+The HiSilicon SoC encapsulates multiple CPU and IO dies. Each CPU cluster
+(CCL) is made up of 4 cpu cores sharing one L3 cache; each CPU die is
+called Super CPU cluster (SCCL) and is made up of 6 CCLs. Each SCCL has
+two HHAs (0 - 1) and four DDRCs (0 - 3), respectively.
+
+HiSilicon SoC uncore PMU driver
+-------------------------------
+
+Each device PMU has separate registers for event counting, control and
+interrupt, and the PMU driver shall register perf PMU drivers like L3C,
+HHA and DDRC etc. The available events and configuration options shall
+be described in the sysfs, see::
+
+/sys/bus/event_source/devices/hisi_sccl{X}_<l3c{Y}/hha{Y}/ddrc{Y}>
+
+The "perf list" command shall list the available events from sysfs.
+
+Each L3C, HHA and DDRC is registered as a separate PMU with perf. The PMU
+name will appear in event listing as hisi_sccl<sccl-id>_module<index-id>.
+where "sccl-id" is the identifier of the SCCL and "index-id" is the index of
+module.
+
+e.g. hisi_sccl3_l3c0/rd_hit_cpipe is READ_HIT_CPIPE event of L3C index #0 in
+SCCL ID #3.
+
+e.g. hisi_sccl1_hha0/rx_operations is RX_OPERATIONS event of HHA index #0 in
+SCCL ID #1.
+
+The driver also provides a "cpumask" sysfs attribute, which shows the CPU core
+ID used to count the uncore PMU event. An "associated_cpus" sysfs attribute is
+also provided to show the CPUs associated with this PMU. The "cpumask" indicates
+the CPUs to open the events, usually as a hint for userspaces tools like perf.
+It only contains one associated CPU from the "associated_cpus".
+
+Example usage of perf::
+
+ $# perf list
+ hisi_sccl3_l3c0/rd_hit_cpipe/ [kernel PMU event]
+ ------------------------------------------
+ hisi_sccl3_l3c0/wr_hit_cpipe/ [kernel PMU event]
+ ------------------------------------------
+ hisi_sccl1_l3c0/rd_hit_cpipe/ [kernel PMU event]
+ ------------------------------------------
+ hisi_sccl1_l3c0/wr_hit_cpipe/ [kernel PMU event]
+ ------------------------------------------
+
+ $# perf stat -a -e hisi_sccl3_l3c0/rd_hit_cpipe/ sleep 5
+ $# perf stat -a -e hisi_sccl3_l3c0/config=0x02/ sleep 5
+
+For HiSilicon uncore PMU v2 whose identifier is 0x30, the topology is the same
+as PMU v1, but some new functions are added to the hardware.
+
+1. L3C PMU supports filtering by core/thread within the cluster which can be
+specified as a bitmap::
+
+ $# perf stat -a -e hisi_sccl3_l3c0/config=0x02,tt_core=0x3/ sleep 5
+
+This will only count the operations from core/thread 0 and 1 in this cluster.
+
+User should not use tt_core_deprecated to specify the core/thread filtering.
+This option is provided for backward compatiblility and only support 8bit
+which may not cover all the core/thread sharing L3C.
+
+2. Tracetag allow the user to chose to count only read, write or atomic
+operations via the tt_req parameeter in perf. The default value counts all
+operations. tt_req is 3bits, 3'b100 represents read operations, 3'b101
+represents write operations, 3'b110 represents atomic store operations and
+3'b111 represents atomic non-store operations, other values are reserved::
+
+ $# perf stat -a -e hisi_sccl3_l3c0/config=0x02,tt_req=0x4/ sleep 5
+
+This will only count the read operations in this cluster.
+
+3. Datasrc allows the user to check where the data comes from. It is 5 bits.
+Some important codes are as follows:
+
+- 5'b00001: comes from L3C in this die;
+- 5'b01000: comes from L3C in the cross-die;
+- 5'b01001: comes from L3C which is in another socket;
+- 5'b01110: comes from the local DDR;
+- 5'b01111: comes from the cross-die DDR;
+- 5'b10000: comes from cross-socket DDR;
+
+etc, it is mainly helpful to find that the data source is nearest from the CPU
+cores. If datasrc_cfg is used in the multi-chips, the datasrc_skt shall be
+configured in perf command::
+
+ $# perf stat -a -e hisi_sccl3_l3c0/config=0xb9,datasrc_cfg=0xE/,
+ hisi_sccl3_l3c0/config=0xb9,datasrc_cfg=0xF/ sleep 5
+
+4. Some HiSilicon SoCs encapsulate multiple CPU and IO dies. Each CPU die
+contains several Compute Clusters (CCLs). The I/O dies are called Super I/O
+clusters (SICL) containing multiple I/O clusters (ICLs). Each CCL/ICL in the
+SoC has a unique ID. Each ID is 11bits, include a 6-bit SCCL-ID and 5-bit
+CCL/ICL-ID. For I/O die, the ICL-ID is followed by:
+
+- 5'b00000: I/O_MGMT_ICL;
+- 5'b00001: Network_ICL;
+- 5'b00011: HAC_ICL;
+- 5'b10000: PCIe_ICL;
+
+5. uring_channel: UC PMU events 0x47~0x59 supports filtering by tx request
+uring channel. It is 2 bits. Some important codes are as follows:
+
+- 2'b11: count the events which sent to the uring_ext (MATA) channel;
+- 2'b01: is the same as 2'b11;
+- 2'b10: count the events which sent to the uring (non-MATA) channel;
+- 2'b00: default value, count the events which sent to both uring and
+ uring_ext channels;
+
+6. ch: NoC PMU supports filtering the event counts of certain transaction
+channel with this option. The current supported channels are as follows:
+
+- 3'b010: Request channel
+- 3'b100: Snoop channel
+- 3'b110: Response channel
+- 3'b111: Data channel
+
+7. tt_en: NoC PMU supports counting only transactions that have tracetag set
+if this option is set. See the 2nd list for more information about tracetag.
+
+For HiSilicon uncore PMU v3 whose identifier is 0x40, some uncore PMUs are
+further divided into parts for finer granularity of tracing, each part has its
+own dedicated PMU, and all such PMUs together cover the monitoring job of events
+on particular uncore device. Such PMUs are described in sysfs with name format
+slightly changed::
+
+/sys/bus/event_source/devices/hisi_sccl{X}_<l3c{Y}_{Z}/ddrc{Y}_{Z}/noc{Y}_{Z}>
+
+Z is the sub-id, indicating different PMUs for part of hardware device.
+
+Usage of most PMUs with different sub-ids are identical. Specially, L3C PMU
+provides ``ext`` option to allow exploration of even finer granual statistics
+of L3C PMU. L3C PMU driver uses that as hint of termination when delivering
+perf command to hardware:
+
+- ext=0: Default, could be used with event names.
+- ext=1 and ext=2: Must be used with event codes, event names are not supported.
+
+An example of perf command could be::
+
+ $# perf stat -a -e hisi_sccl0_l3c1_0/rd_spipe/ sleep 5
+
+or::
+
+ $# perf stat -a -e hisi_sccl0_l3c1_0/event=0x1,ext=1/ sleep 5
+
+As above, ``hisi_sccl0_l3c1_0`` locates PMU of Super CPU CLuster 0, L3 cache 1
+pipe0.
+
+First command locates the first part of L3C since ``ext=0`` is implied by
+default. Second command issues the counting on another part of L3C with the
+event ``0x1``.
+
+Users could configure IDs to count data come from specific CCL/ICL, by setting
+srcid_cmd & srcid_msk, and data desitined for specific CCL/ICL by setting
+tgtid_cmd & tgtid_msk. A set bit in srcid_msk/tgtid_msk means the PMU will not
+check the bit when matching against the srcid_cmd/tgtid_cmd.
+
+If all of these options are disabled, it can works by the default value that
+doesn't distinguish the filter condition and ID information and will return
+the total counter values in the PMU counters.
+
+The current driver does not support sampling. So "perf record" is unsupported.
+Also attach to a task is unsupported as the events are all uncore.
+
+Note: Please contact the maintainer for a complete list of events supported for
+the PMU devices in the SoC and its information if needed.
diff --git a/Documentation/admin-guide/perf/hns3-pmu.rst b/Documentation/admin-guide/perf/hns3-pmu.rst
new file mode 100644
index 000000000..1195e570f
--- /dev/null
+++ b/Documentation/admin-guide/perf/hns3-pmu.rst
@@ -0,0 +1,136 @@
+======================================
+HNS3 Performance Monitoring Unit (PMU)
+======================================
+
+HNS3(HiSilicon network system 3) Performance Monitoring Unit (PMU) is an
+End Point device to collect performance statistics of HiSilicon SoC NIC.
+On Hip09, each SICL(Super I/O cluster) has one PMU device.
+
+HNS3 PMU supports collection of performance statistics such as bandwidth,
+latency, packet rate and interrupt rate.
+
+Each HNS3 PMU supports 8 hardware events.
+
+HNS3 PMU driver
+===============
+
+The HNS3 PMU driver registers a perf PMU with the name of its sicl id.::
+
+ /sys/bus/event_source/devices/hns3_pmu_sicl_<sicl_id>
+
+PMU driver provides description of available events, filter modes, format,
+identifier and cpumask in sysfs.
+
+The "events" directory describes the event code of all supported events
+shown in perf list.
+
+The "filtermode" directory describes the supported filter modes of each
+event.
+
+The "format" directory describes all formats of the config (events) and
+config1 (filter options) fields of the perf_event_attr structure.
+
+The "identifier" file shows version of PMU hardware device.
+
+The "bdf_min" and "bdf_max" files show the supported bdf range of each
+pmu device.
+
+The "hw_clk_freq" file shows the hardware clock frequency of each pmu
+device.
+
+Example usage of checking event code and subevent code::
+
+ $# cat /sys/bus/event_source/devices/hns3_pmu_sicl_0/events/dly_tx_normal_to_mac_time
+ config=0x00204
+ $# cat /sys/bus/event_source/devices/hns3_pmu_sicl_0/events/dly_tx_normal_to_mac_packet_num
+ config=0x10204
+
+Each performance statistic has a pair of events to get two values to
+calculate real performance data in userspace.
+
+The bits 0~15 of config (here 0x0204) are the true hardware event code. If
+two events have same value of bits 0~15 of config, that means they are
+event pair. And the bit 16 of config indicates getting counter 0 or
+counter 1 of hardware event.
+
+After getting two values of event pair in userspace, the formula of
+computation to calculate real performance data is:::
+
+ counter 0 / counter 1
+
+Example usage of checking supported filter mode::
+
+ $# cat /sys/bus/event_source/devices/hns3_pmu_sicl_0/filtermode/bw_ssu_rpu_byte_num
+ filter mode supported: global/port/port-tc/func/func-queue/
+
+Example usage of perf::
+
+ $# perf list
+ hns3_pmu_sicl_0/bw_ssu_rpu_byte_num/ [kernel PMU event]
+ hns3_pmu_sicl_0/bw_ssu_rpu_time/ [kernel PMU event]
+ ------------------------------------------
+
+ $# perf stat -g -e hns3_pmu_sicl_0/bw_ssu_rpu_byte_num,global=1/ -e hns3_pmu_sicl_0/bw_ssu_rpu_time,global=1/ -I 1000
+ or
+ $# perf stat -g -e hns3_pmu_sicl_0/config=0x00002,global=1/ -e hns3_pmu_sicl_0/config=0x10002,global=1/ -I 1000
+
+
+Filter modes
+--------------
+
+1. global mode
+PMU collect performance statistics for all HNS3 PCIe functions of IO DIE.
+Set the "global" filter option to 1 will enable this mode.
+Example usage of perf::
+
+ $# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,global=1/ -I 1000
+
+2. port mode
+PMU collect performance statistic of one whole physical port. The port id
+is same as mac id. The "tc" filter option must be set to 0xF in this mode,
+here tc stands for traffic class.
+
+Example usage of perf::
+
+ $# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,port=0,tc=0xF/ -I 1000
+
+3. port-tc mode
+PMU collect performance statistic of one tc of physical port. The port id
+is same as mac id. The "tc" filter option must be set to 0 ~ 7 in this
+mode.
+Example usage of perf::
+
+ $# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,port=0,tc=0/ -I 1000
+
+4. func mode
+PMU collect performance statistic of one PF/VF. The function id is BDF of
+PF/VF, its conversion formula::
+
+ func = (bus << 8) + (device << 3) + (function)
+
+for example:
+ BDF func
+ 35:00.0 0x3500
+ 35:00.1 0x3501
+ 35:01.0 0x3508
+
+In this mode, the "queue" filter option must be set to 0xFFFF.
+Example usage of perf::
+
+ $# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,bdf=0x3500,queue=0xFFFF/ -I 1000
+
+5. func-queue mode
+PMU collect performance statistic of one queue of PF/VF. The function id
+is BDF of PF/VF, the "queue" filter option must be set to the exact queue
+id of function.
+Example usage of perf::
+
+ $# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,bdf=0x3500,queue=0/ -I 1000
+
+6. func-intr mode
+PMU collect performance statistic of one interrupt of PF/VF. The function
+id is BDF of PF/VF, the "intr" filter option must be set to the exact
+interrupt id of function.
+Example usage of perf::
+
+ $# perf stat -a -e hns3_pmu_sicl_0/config=0x00301,bdf=0x3500,intr=0/ -I 1000
diff --git a/Documentation/admin-guide/perf/imx-ddr.rst b/Documentation/admin-guide/perf/imx-ddr.rst
new file mode 100644
index 000000000..77418ae5a
--- /dev/null
+++ b/Documentation/admin-guide/perf/imx-ddr.rst
@@ -0,0 +1,100 @@
+=====================================================
+Freescale i.MX8 DDR Performance Monitoring Unit (PMU)
+=====================================================
+
+There are no performance counters inside the DRAM controller, so performance
+signals are brought out to the edge of the controller where a set of 4 x 32 bit
+counters is implemented. This is controlled by the CSV modes programmed in counter
+control register which causes a large number of PERF signals to be generated.
+
+Selection of the value for each counter is done via the config registers. There
+is one register for each counter. Counter 0 is special in that it always counts
+“time” and when expired causes a lock on itself and the other counters and an
+interrupt is raised. If any other counter overflows, it continues counting, and
+no interrupt is raised.
+
+The "format" directory describes format of the config (event ID) and config1/2
+(AXI filter setting) fields of the perf_event_attr structure, see /sys/bus/event_source/
+devices/imx8_ddr0/format/. The "events" directory describes the events types
+hardware supported that can be used with perf tool, see /sys/bus/event_source/
+devices/imx8_ddr0/events/. The "caps" directory describes filter features implemented
+in DDR PMU, see /sys/bus/events_source/devices/imx8_ddr0/caps/.
+
+ .. code-block:: bash
+
+ perf stat -a -e imx8_ddr0/cycles/ cmd
+ perf stat -a -e imx8_ddr0/read/,imx8_ddr0/write/ cmd
+
+AXI filtering is only used by CSV modes 0x41 (axid-read) and 0x42 (axid-write)
+to count reading or writing matches filter setting. Filter setting is various
+from different DRAM controller implementations, which is distinguished by quirks
+in the driver. You also can dump info from userspace, "caps" directory show the
+type of AXI filter (filter, enhanced_filter and super_filter). Value 0 for
+un-supported, and value 1 for supported.
+
+* With DDR_CAP_AXI_ID_FILTER quirk(filter: 1, enhanced_filter: 0, super_filter: 0).
+ Filter is defined with two configuration parts:
+ --AXI_ID defines AxID matching value.
+ --AXI_MASKING defines which bits of AxID are meaningful for the matching.
+
+ - 0: corresponding bit is masked.
+ - 1: corresponding bit is not masked, i.e. used to do the matching.
+
+ AXI_ID and AXI_MASKING are mapped on DPCR1 register in performance counter.
+ When non-masked bits are matching corresponding AXI_ID bits then counter is
+ incremented. Perf counter is incremented if::
+
+ AxID && AXI_MASKING == AXI_ID && AXI_MASKING
+
+ This filter doesn't support filter different AXI ID for axid-read and axid-write
+ event at the same time as this filter is shared between counters.
+
+ .. code-block:: bash
+
+ perf stat -a -e imx8_ddr0/axid-read,axi_mask=0xMMMM,axi_id=0xDDDD/ cmd
+ perf stat -a -e imx8_ddr0/axid-write,axi_mask=0xMMMM,axi_id=0xDDDD/ cmd
+
+ .. note::
+
+ axi_mask is inverted in userspace(i.e. set bits are bits to mask), and
+ it will be reverted in driver automatically. so that the user can just specify
+ axi_id to monitor a specific id, rather than having to specify axi_mask.
+
+ .. code-block:: bash
+
+ perf stat -a -e imx8_ddr0/axid-read,axi_id=0x12/ cmd, which will monitor ARID=0x12
+
+* With DDR_CAP_AXI_ID_FILTER_ENHANCED quirk(filter: 1, enhanced_filter: 1, super_filter: 0).
+ This is an extension to the DDR_CAP_AXI_ID_FILTER quirk which permits
+ counting the number of bytes (as opposed to the number of bursts) from DDR
+ read and write transactions concurrently with another set of data counters.
+
+* With DDR_CAP_AXI_ID_PORT_CHANNEL_FILTER quirk(filter: 0, enhanced_filter: 0, super_filter: 1).
+ There is a limitation in previous AXI filter, it cannot filter different IDs
+ at the same time as the filter is shared between counters. This quirk is the
+ extension of AXI ID filter. One improvement is that counter 1-3 has their own
+ filter, means that it supports concurrently filter various IDs. Another
+ improvement is that counter 1-3 supports AXI PORT and CHANNEL selection. Support
+ selecting address channel or data channel.
+
+ Filter is defined with 2 configuration registers per counter 1-3.
+ --Counter N MASK COMP register - including AXI_ID and AXI_MASKING.
+ --Counter N MUX CNTL register - including AXI CHANNEL and AXI PORT.
+
+ - 0: address channel
+ - 1: data channel
+
+ PMU in DDR subsystem, only one single port0 exists, so axi_port is reserved
+ which should be 0.
+
+ .. code-block:: bash
+
+ perf stat -a -e imx8_ddr0/axid-read,axi_mask=0xMMMM,axi_id=0xDDDD,axi_channel=0xH/ cmd
+ perf stat -a -e imx8_ddr0/axid-write,axi_mask=0xMMMM,axi_id=0xDDDD,axi_channel=0xH/ cmd
+
+ .. note::
+
+ axi_channel is inverted in userspace, and it will be reverted in driver
+ automatically. So that users do not need specify axi_channel if want to
+ monitor data channel from DDR transactions, since data channel is more
+ meaningful.
diff --git a/Documentation/admin-guide/perf/index.rst b/Documentation/admin-guide/perf/index.rst
new file mode 100644
index 000000000..aa12708dd
--- /dev/null
+++ b/Documentation/admin-guide/perf/index.rst
@@ -0,0 +1,33 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+===========================
+Performance monitor support
+===========================
+
+.. toctree::
+ :maxdepth: 1
+
+ hisi-pmu
+ hisi-pcie-pmu
+ hns3-pmu
+ imx-ddr
+ qcom_l2_pmu
+ qcom_l3_pmu
+ starfive_starlink_pmu
+ mrvl-odyssey-ddr-pmu
+ mrvl-odyssey-tad-pmu
+ arm-ccn
+ arm-cmn
+ arm-ni
+ xgene-pmu
+ arm_dsu_pmu
+ thunderx2-pmu
+ alibaba_pmu
+ dwc_pcie_pmu
+ nvidia-tegra241-pmu
+ nvidia-tegra410-pmu
+ meson-ddr-pmu
+ cxl
+ ampere_cspmu
+ mrvl-pem-pmu
+ fujitsu_uncore_pmu
diff --git a/Documentation/admin-guide/perf/meson-ddr-pmu.rst b/Documentation/admin-guide/perf/meson-ddr-pmu.rst
new file mode 100644
index 000000000..8e71be1d6
--- /dev/null
+++ b/Documentation/admin-guide/perf/meson-ddr-pmu.rst
@@ -0,0 +1,70 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+===========================================================
+Amlogic SoC DDR Bandwidth Performance Monitoring Unit (PMU)
+===========================================================
+
+The Amlogic Meson G12 SoC contains a bandwidth monitor inside DRAM controller.
+The monitor includes 4 channels. Each channel can count the request accessing
+DRAM. The channel can count up to 3 AXI port simultaneously. It can be helpful
+to show if the performance bottleneck is on DDR bandwidth.
+
+Currently, this driver supports the following 5 perf events:
+
++ meson_ddr_bw/total_rw_bytes/
++ meson_ddr_bw/chan_1_rw_bytes/
++ meson_ddr_bw/chan_2_rw_bytes/
++ meson_ddr_bw/chan_3_rw_bytes/
++ meson_ddr_bw/chan_4_rw_bytes/
+
+meson_ddr_bw/chan_{1,2,3,4}_rw_bytes/ events are channel-specific events.
+Each channel support filtering, which can let the channel to monitor
+individual IP module in SoC.
+
+Below are DDR access request event filter keywords:
+
++ arm - from CPU
++ vpu_read1 - from OSD + VPP read
++ gpu - from 3D GPU
++ pcie - from PCIe controller
++ hdcp - from HDCP controller
++ hevc_front - from HEVC codec front end
++ usb3_0 - from USB3.0 controller
++ hevc_back - from HEVC codec back end
++ h265enc - from HEVC encoder
++ vpu_read2 - from DI read
++ vpu_write1 - from VDIN write
++ vpu_write2 - from di write
++ vdec - from legacy codec video decoder
++ hcodec - from H264 encoder
++ ge2d - from ge2d
++ spicc1 - from SPI controller 1
++ usb0 - from USB2.0 controller 0
++ dma - from system DMA controller 1
++ arb0 - from arb0
++ sd_emmc_b - from SD eMMC b controller
++ usb1 - from USB2.0 controller 1
++ audio - from Audio module
++ sd_emmc_c - from SD eMMC c controller
++ spicc2 - from SPI controller 2
++ ethernet - from Ethernet controller
+
+
+Examples:
+
+ + Show the total DDR bandwidth per seconds:
+
+ .. code-block:: bash
+
+ perf stat -a -e meson_ddr_bw/total_rw_bytes/ -I 1000 sleep 10
+
+
+ + Show individual DDR bandwidth from CPU and GPU respectively, as well as
+ sum of them:
+
+ .. code-block:: bash
+
+ perf stat -a -e meson_ddr_bw/chan_1_rw_bytes,arm=1/ -I 1000 sleep 10
+ perf stat -a -e meson_ddr_bw/chan_2_rw_bytes,gpu=1/ -I 1000 sleep 10
+ perf stat -a -e meson_ddr_bw/chan_3_rw_bytes,arm=1,gpu=1/ -I 1000 sleep 10
+
diff --git a/Documentation/admin-guide/perf/mrvl-odyssey-ddr-pmu.rst b/Documentation/admin-guide/perf/mrvl-odyssey-ddr-pmu.rst
new file mode 100644
index 000000000..2e817593a
--- /dev/null
+++ b/Documentation/admin-guide/perf/mrvl-odyssey-ddr-pmu.rst
@@ -0,0 +1,80 @@
+===================================================================
+Marvell Odyssey DDR PMU Performance Monitoring Unit (PMU UNCORE)
+===================================================================
+
+Odyssey DRAM Subsystem supports eight counters for monitoring performance
+and software can program those counters to monitor any of the defined
+performance events. Supported performance events include those counted
+at the interface between the DDR controller and the PHY, interface between
+the DDR Controller and the CHI interconnect, or within the DDR Controller.
+
+Additionally DSS also supports two fixed performance event counters, one
+for ddr reads and the other for ddr writes.
+
+The counter will be operating in either manual or auto mode.
+
+The PMU driver exposes the available events and format options under sysfs::
+
+ /sys/bus/event_source/devices/mrvl_ddr_pmu_<>/events/
+ /sys/bus/event_source/devices/mrvl_ddr_pmu_<>/format/
+
+Examples::
+
+ $ perf list | grep ddr
+ mrvl_ddr_pmu_<>/ddr_act_bypass_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_bsm_alloc/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_bsm_starvation/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_cam_active_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_cam_mwr/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_cam_rd_active_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_cam_rd_or_wr_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_cam_read/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_cam_wr_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_cam_write/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_capar_error/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_crit_ref/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_ddr_reads/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_ddr_writes/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_dfi_cmd_is_retry/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_dfi_cycles/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_dfi_parity_poison/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_dfi_rd_data_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_dfi_wr_data_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_dqsosc_mpc/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_dqsosc_mrr/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_enter_mpsm/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_enter_powerdown/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_enter_selfref/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_hif_pri_rdaccess/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_hif_rd_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_hif_rd_or_wr_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_hif_rmw_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_hif_wr_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_hpri_sched_rd_crit_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_load_mode/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_lpri_sched_rd_crit_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_precharge/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_precharge_for_other/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_precharge_for_rdwr/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_raw_hazard/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_rd_bypass_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_rd_crc_error/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_rd_uc_ecc_error/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_rdwr_transitions/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_refresh/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_retry_fifo_full/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_spec_ref/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_tcr_mrr/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_war_hazard/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_waw_hazard/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_win_limit_reached_rd/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_win_limit_reached_wr/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_wr_crc_error/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_wr_trxn_crit_access/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_write_combine/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_zqcl/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_zqlatch/ [Kernel PMU event]
+ mrvl_ddr_pmu_<>/ddr_zqstart/ [Kernel PMU event]
+
+ $ perf stat -e ddr_cam_read,ddr_cam_write,ddr_cam_active_access,ddr_cam
+ rd_or_wr_access,ddr_cam_rd_active_access,ddr_cam_mwr <workload>
diff --git a/Documentation/admin-guide/perf/mrvl-odyssey-tad-pmu.rst b/Documentation/admin-guide/perf/mrvl-odyssey-tad-pmu.rst
new file mode 100644
index 000000000..ad1975b14
--- /dev/null
+++ b/Documentation/admin-guide/perf/mrvl-odyssey-tad-pmu.rst
@@ -0,0 +1,37 @@
+====================================================================
+Marvell Odyssey LLC-TAD Performance Monitoring Unit (PMU UNCORE)
+====================================================================
+
+Each TAD provides eight 64-bit counters for monitoring
+cache behavior.The driver always configures the same counter for
+all the TADs. The user would end up effectively reserving one of
+eight counters in every TAD to look across all TADs.
+The occurrences of events are aggregated and presented to the user
+at the end of running the workload. The driver does not provide a
+way for the user to partition TADs so that different TADs are used for
+different applications.
+
+The performance events reflect various internal or interface activities.
+By combining the values from multiple performance counters, cache
+performance can be measured in terms such as: cache miss rate, cache
+allocations, interface retry rate, internal resource occupancy, etc.
+
+The PMU driver exposes the available events and format options under sysfs::
+
+ /sys/bus/event_source/devices/tad/events/
+ /sys/bus/event_source/devices/tad/format/
+
+Examples::
+
+ $ perf list | grep tad
+ tad/tad_alloc_any/ [Kernel PMU event]
+ tad/tad_alloc_dtg/ [Kernel PMU event]
+ tad/tad_alloc_ltg/ [Kernel PMU event]
+ tad/tad_hit_any/ [Kernel PMU event]
+ tad/tad_hit_dtg/ [Kernel PMU event]
+ tad/tad_hit_ltg/ [Kernel PMU event]
+ tad/tad_req_msh_in_exlmn/ [Kernel PMU event]
+ tad/tad_tag_rd/ [Kernel PMU event]
+ tad/tad_tot_cycle/ [Kernel PMU event]
+
+ $ perf stat -e tad_alloc_dtg,tad_alloc_ltg,tad_alloc_any,tad_hit_dtg,tad_hit_ltg,tad_hit_any,tad_tag_rd <workload>
diff --git a/Documentation/admin-guide/perf/mrvl-pem-pmu.rst b/Documentation/admin-guide/perf/mrvl-pem-pmu.rst
new file mode 100644
index 000000000..c39007149
--- /dev/null
+++ b/Documentation/admin-guide/perf/mrvl-pem-pmu.rst
@@ -0,0 +1,56 @@
+=================================================================
+Marvell Odyssey PEM Performance Monitoring Unit (PMU UNCORE)
+=================================================================
+
+The PCI Express Interface Units(PEM) are associated with a corresponding
+monitoring unit. This includes performance counters to track various
+characteristics of the data that is transmitted over the PCIe link.
+
+The counters track inbound and outbound transactions which
+includes separate counters for posted/non-posted/completion TLPs.
+Also, inbound and outbound memory read requests along with their
+latencies can also be monitored. Address Translation Services(ATS)events
+such as ATS Translation, ATS Page Request, ATS Invalidation along with
+their corresponding latencies are also tracked.
+
+There are separate 64 bit counters to measure posted/non-posted/completion
+tlps in inbound and outbound transactions. ATS events are measured by
+different counters.
+
+The PMU driver exposes the available events and format options under sysfs,
+/sys/bus/event_source/devices/mrvl_pcie_rc_pmu_<>/events/
+/sys/bus/event_source/devices/mrvl_pcie_rc_pmu_<>/format/
+
+Examples::
+
+ # perf list | grep mrvl_pcie_rc_pmu
+ mrvl_pcie_rc_pmu_<>/ats_inv/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ats_inv_latency/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ats_pri/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ats_pri_latency/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ats_trans/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ats_trans_latency/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_inflight/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_reads/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_req_no_ro_ebus/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_req_no_ro_ncb/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_tlp_cpl_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_tlp_dwords_cpl_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_tlp_dwords_npr/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_tlp_dwords_pr/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_tlp_npr/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ib_tlp_pr/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_inflight_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_merges_cpl_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_merges_npr_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_merges_pr_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_reads_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_tlp_cpl_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_tlp_dwords_cpl_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_tlp_dwords_npr_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_tlp_dwords_pr_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_tlp_npr_partid/ [Kernel PMU event]
+ mrvl_pcie_rc_pmu_<>/ob_tlp_pr_partid/ [Kernel PMU event]
+
+
+ # perf stat -e ib_inflight,ib_reads,ib_req_no_ro_ebus,ib_req_no_ro_ncb <workload>
diff --git a/Documentation/admin-guide/perf/nvidia-tegra241-pmu.rst b/Documentation/admin-guide/perf/nvidia-tegra241-pmu.rst
new file mode 100644
index 000000000..fad5bc4ce
--- /dev/null
+++ b/Documentation/admin-guide/perf/nvidia-tegra241-pmu.rst
@@ -0,0 +1,333 @@
+============================================================
+NVIDIA Tegra241 SoC Uncore Performance Monitoring Unit (PMU)
+============================================================
+
+The NVIDIA Tegra241 SoC includes various system PMUs to measure key performance
+metrics like memory bandwidth, latency, and utilization:
+
+* Scalable Coherency Fabric (SCF)
+* NVLink-C2C0
+* NVLink-C2C1
+* CNVLink
+* PCIE
+
+PMU Driver
+----------
+
+The PMUs in this document are based on ARM CoreSight PMU Architecture as
+described in document: ARM IHI 0091. Since this is a standard architecture, the
+PMUs are managed by a common driver "arm-cs-arch-pmu". This driver describes
+the available events and configuration of each PMU in sysfs. Please see the
+sections below to get the sysfs path of each PMU. Like other uncore PMU drivers,
+the driver provides "cpumask" sysfs attribute to show the CPU id used to handle
+the PMU event. There is also "associated_cpus" sysfs attribute, which contains a
+list of CPUs associated with the PMU instance.
+
+.. _SCF_PMU_Section:
+
+SCF PMU
+-------
+
+The SCF PMU monitors system level cache events, CPU traffic, and
+strongly-ordered (SO) PCIE write traffic to local/remote memory. Please see
+:ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` for more info about the PMU
+traffic coverage.
+
+The events and configuration options of this PMU device are described in sysfs,
+see /sys/bus/event_source/devices/nvidia_scf_pmu_<socket-id>.
+
+Example usage:
+
+* Count event id 0x0 in socket 0::
+
+ perf stat -a -e nvidia_scf_pmu_0/event=0x0/
+
+* Count event id 0x0 in socket 1::
+
+ perf stat -a -e nvidia_scf_pmu_1/event=0x0/
+
+NVLink-C2C0 PMU
+--------------------
+
+The NVLink-C2C0 PMU monitors incoming traffic from a GPU/CPU connected with
+NVLink-C2C (Chip-2-Chip) interconnect. The type of traffic captured by this PMU
+varies dependent on the chip configuration:
+
+* NVIDIA Grace Hopper Superchip: Hopper GPU is connected with Grace SoC.
+
+ In this config, the PMU captures GPU ATS translated or EGM traffic from the GPU.
+
+* NVIDIA Grace CPU Superchip: two Grace CPU SoCs are connected.
+
+ In this config, the PMU captures read and relaxed ordered (RO) writes from
+ PCIE device of the remote SoC.
+
+Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` for more info about
+the PMU traffic coverage.
+
+The events and configuration options of this PMU device are described in sysfs,
+see /sys/bus/event_source/devices/nvidia_nvlink_c2c0_pmu_<socket-id>.
+
+Example usage:
+
+* Count event id 0x0 from the GPU/CPU connected with socket 0::
+
+ perf stat -a -e nvidia_nvlink_c2c0_pmu_0/event=0x0/
+
+* Count event id 0x0 from the GPU/CPU connected with socket 1::
+
+ perf stat -a -e nvidia_nvlink_c2c0_pmu_1/event=0x0/
+
+* Count event id 0x0 from the GPU/CPU connected with socket 2::
+
+ perf stat -a -e nvidia_nvlink_c2c0_pmu_2/event=0x0/
+
+* Count event id 0x0 from the GPU/CPU connected with socket 3::
+
+ perf stat -a -e nvidia_nvlink_c2c0_pmu_3/event=0x0/
+
+The NVLink-C2C has two ports that can be connected to one GPU (occupying both
+ports) or to two GPUs (one GPU per port). The user can use "port" bitmap
+parameter to select the port(s) to monitor. Each bit represents the port number,
+e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. The
+PMU will monitor both ports by default if not specified.
+
+Example for port filtering:
+
+* Count event id 0x0 from the GPU connected with socket 0 on port 0::
+
+ perf stat -a -e nvidia_nvlink_c2c0_pmu_0/event=0x0,port=0x1/
+
+* Count event id 0x0 from the GPUs connected with socket 0 on port 0 and port 1::
+
+ perf stat -a -e nvidia_nvlink_c2c0_pmu_0/event=0x0,port=0x3/
+
+NVLink-C2C1 PMU
+-------------------
+
+The NVLink-C2C1 PMU monitors incoming traffic from a GPU connected with
+NVLink-C2C (Chip-2-Chip) interconnect. This PMU captures untranslated GPU
+traffic, in contrast with NvLink-C2C0 PMU that captures ATS translated traffic.
+Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` for more info about
+the PMU traffic coverage.
+
+The events and configuration options of this PMU device are described in sysfs,
+see /sys/bus/event_source/devices/nvidia_nvlink_c2c1_pmu_<socket-id>.
+
+Example usage:
+
+* Count event id 0x0 from the GPU connected with socket 0::
+
+ perf stat -a -e nvidia_nvlink_c2c1_pmu_0/event=0x0/
+
+* Count event id 0x0 from the GPU connected with socket 1::
+
+ perf stat -a -e nvidia_nvlink_c2c1_pmu_1/event=0x0/
+
+* Count event id 0x0 from the GPU connected with socket 2::
+
+ perf stat -a -e nvidia_nvlink_c2c1_pmu_2/event=0x0/
+
+* Count event id 0x0 from the GPU connected with socket 3::
+
+ perf stat -a -e nvidia_nvlink_c2c1_pmu_3/event=0x0/
+
+The NVLink-C2C has two ports that can be connected to one GPU (occupying both
+ports) or to two GPUs (one GPU per port). The user can use "port" bitmap
+parameter to select the port(s) to monitor. Each bit represents the port number,
+e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. The
+PMU will monitor both ports by default if not specified.
+
+Example for port filtering:
+
+* Count event id 0x0 from the GPU connected with socket 0 on port 0::
+
+ perf stat -a -e nvidia_nvlink_c2c1_pmu_0/event=0x0,port=0x1/
+
+* Count event id 0x0 from the GPUs connected with socket 0 on port 0 and port 1::
+
+ perf stat -a -e nvidia_nvlink_c2c1_pmu_0/event=0x0,port=0x3/
+
+CNVLink PMU
+---------------
+
+The CNVLink PMU monitors traffic from GPU and PCIE device on remote sockets
+to local memory. For PCIE traffic, this PMU captures read and relaxed ordered
+(RO) write traffic. Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section`
+for more info about the PMU traffic coverage.
+
+The events and configuration options of this PMU device are described in sysfs,
+see /sys/bus/event_source/devices/nvidia_cnvlink_pmu_<socket-id>.
+
+Each SoC socket can be connected to one or more sockets via CNVLink. The user can
+use "rem_socket" bitmap parameter to select the remote socket(s) to monitor.
+Each bit represents the socket number, e.g. "rem_socket=0xE" corresponds to
+socket 1 to 3. The PMU will monitor all remote sockets by default if not
+specified.
+/sys/bus/event_source/devices/nvidia_cnvlink_pmu_<socket-id>/format/rem_socket
+shows the valid bits that can be set in the "rem_socket" parameter.
+
+The PMU can not distinguish the remote traffic initiator, therefore it does not
+provide filter to select the traffic source to monitor. It reports combined
+traffic from remote GPU and PCIE devices.
+
+Example usage:
+
+* Count event id 0x0 for the traffic from remote socket 1, 2, and 3 to socket 0::
+
+ perf stat -a -e nvidia_cnvlink_pmu_0/event=0x0,rem_socket=0xE/
+
+* Count event id 0x0 for the traffic from remote socket 0, 2, and 3 to socket 1::
+
+ perf stat -a -e nvidia_cnvlink_pmu_1/event=0x0,rem_socket=0xD/
+
+* Count event id 0x0 for the traffic from remote socket 0, 1, and 3 to socket 2::
+
+ perf stat -a -e nvidia_cnvlink_pmu_2/event=0x0,rem_socket=0xB/
+
+* Count event id 0x0 for the traffic from remote socket 0, 1, and 2 to socket 3::
+
+ perf stat -a -e nvidia_cnvlink_pmu_3/event=0x0,rem_socket=0x7/
+
+
+PCIE PMU
+------------
+
+The PCIE PMU monitors all read/write traffic from PCIE root ports to
+local/remote memory. Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section`
+for more info about the PMU traffic coverage.
+
+The events and configuration options of this PMU device are described in sysfs,
+see /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>.
+
+Each SoC socket can support multiple root ports. The user can use
+"root_port" bitmap parameter to select the port(s) to monitor, i.e.
+"root_port=0xF" corresponds to root port 0 to 3. The PMU will monitor all root
+ports by default if not specified.
+/sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>/format/root_port
+shows the valid bits that can be set in the "root_port" parameter.
+
+Example usage:
+
+* Count event id 0x0 from root port 0 and 1 of socket 0::
+
+ perf stat -a -e nvidia_pcie_pmu_0/event=0x0,root_port=0x3/
+
+* Count event id 0x0 from root port 0 and 1 of socket 1::
+
+ perf stat -a -e nvidia_pcie_pmu_1/event=0x0,root_port=0x3/
+
+.. _NVIDIA_Uncore_PMU_Traffic_Coverage_Section:
+
+Traffic Coverage
+----------------
+
+The PMU traffic coverage may vary dependent on the chip configuration:
+
+* **NVIDIA Grace Hopper Superchip**: Hopper GPU is connected with Grace SoC.
+
+ Example configuration with two Grace SoCs::
+
+ ********************************* *********************************
+ * SOCKET-A * * SOCKET-B *
+ * * * *
+ * :::::::: * * :::::::: *
+ * : PCIE : * * : PCIE : *
+ * :::::::: * * :::::::: *
+ * | * * | *
+ * | * * | *
+ * ::::::: ::::::::: * * ::::::::: ::::::: *
+ * : : : : * * : : : : *
+ * : GPU :<--NVLink-->: Grace :<---CNVLink--->: Grace :<--NVLink-->: GPU : *
+ * : : C2C : SoC : * * : SoC : C2C : : *
+ * ::::::: ::::::::: * * ::::::::: ::::::: *
+ * | | * * | | *
+ * | | * * | | *
+ * &&&&&&&& &&&&&&&& * * &&&&&&&& &&&&&&&& *
+ * & GMEM & & CMEM & * * & CMEM & & GMEM & *
+ * &&&&&&&& &&&&&&&& * * &&&&&&&& &&&&&&&& *
+ * * * *
+ ********************************* *********************************
+
+ GMEM = GPU Memory (e.g. HBM)
+ CMEM = CPU Memory (e.g. LPDDR5X)
+
+ |
+ | Following table contains traffic coverage of Grace SoC PMU in socket-A:
+
+ ::
+
+ +--------------+-------+-----------+-----------+-----+----------+----------+
+ | | Source |
+ + +-------+-----------+-----------+-----+----------+----------+
+ | Destination | |GPU ATS |GPU Not-ATS| | Socket-B | Socket-B |
+ | |PCI R/W|Translated,|Translated | CPU | CPU/PCIE1| GPU/PCIE2|
+ | | |EGM | | | | |
+ +==============+=======+===========+===========+=====+==========+==========+
+ | Local | PCIE |NVLink-C2C0|NVLink-C2C1| SCF | SCF PMU | CNVLink |
+ | SYSRAM/CMEM | PMU |PMU |PMU | PMU | | PMU |
+ +--------------+-------+-----------+-----------+-----+----------+----------+
+ | Local GMEM | PCIE | N/A |NVLink-C2C1| SCF | SCF PMU | CNVLink |
+ | | PMU | |PMU | PMU | | PMU |
+ +--------------+-------+-----------+-----------+-----+----------+----------+
+ | Remote | PCIE |NVLink-C2C0|NVLink-C2C1| SCF | | |
+ | SYSRAM/CMEM | PMU |PMU |PMU | PMU | N/A | N/A |
+ | over CNVLink | | | | | | |
+ +--------------+-------+-----------+-----------+-----+----------+----------+
+ | Remote GMEM | PCIE |NVLink-C2C0|NVLink-C2C1| SCF | | |
+ | over CNVLink | PMU |PMU |PMU | PMU | N/A | N/A |
+ +--------------+-------+-----------+-----------+-----+----------+----------+
+
+ PCIE1 traffic represents strongly ordered (SO) writes.
+ PCIE2 traffic represents reads and relaxed ordered (RO) writes.
+
+* **NVIDIA Grace CPU Superchip**: two Grace CPU SoCs are connected.
+
+ Example configuration with two Grace SoCs::
+
+ ******************* *******************
+ * SOCKET-A * * SOCKET-B *
+ * * * *
+ * :::::::: * * :::::::: *
+ * : PCIE : * * : PCIE : *
+ * :::::::: * * :::::::: *
+ * | * * | *
+ * | * * | *
+ * ::::::::: * * ::::::::: *
+ * : : * * : : *
+ * : Grace :<--------NVLink------->: Grace : *
+ * : SoC : * C2C * : SoC : *
+ * ::::::::: * * ::::::::: *
+ * | * * | *
+ * | * * | *
+ * &&&&&&&& * * &&&&&&&& *
+ * & CMEM & * * & CMEM & *
+ * &&&&&&&& * * &&&&&&&& *
+ * * * *
+ ******************* *******************
+
+ GMEM = GPU Memory (e.g. HBM)
+ CMEM = CPU Memory (e.g. LPDDR5X)
+
+ |
+ | Following table contains traffic coverage of Grace SoC PMU in socket-A:
+
+ ::
+
+ +-----------------+-----------+---------+----------+-------------+
+ | | Source |
+ + +-----------+---------+----------+-------------+
+ | Destination | | | Socket-B | Socket-B |
+ | | PCI R/W | CPU | CPU/PCIE1| PCIE2 |
+ | | | | | |
+ +=================+===========+=========+==========+=============+
+ | Local | PCIE PMU | SCF PMU | SCF PMU | NVLink-C2C0 |
+ | SYSRAM/CMEM | | | | PMU |
+ +-----------------+-----------+---------+----------+-------------+
+ | Remote | | | | |
+ | SYSRAM/CMEM | PCIE PMU | SCF PMU | N/A | N/A |
+ | over NVLink-C2C | | | | |
+ +-----------------+-----------+---------+----------+-------------+
+
+ PCIE1 traffic represents strongly ordered (SO) writes.
+ PCIE2 traffic represents reads and relaxed ordered (RO) writes.
diff --git a/Documentation/admin-guide/perf/nvidia-tegra410-pmu.rst b/Documentation/admin-guide/perf/nvidia-tegra410-pmu.rst
new file mode 100644
index 000000000..0656223b6
--- /dev/null
+++ b/Documentation/admin-guide/perf/nvidia-tegra410-pmu.rst
@@ -0,0 +1,522 @@
+=====================================================================
+NVIDIA Tegra410 SoC Uncore Performance Monitoring Unit (PMU)
+=====================================================================
+
+The NVIDIA Tegra410 SoC includes various system PMUs to measure key performance
+metrics like memory bandwidth, latency, and utilization:
+
+* Unified Coherence Fabric (UCF)
+* PCIE
+* PCIE-TGT
+* CPU Memory (CMEM) Latency
+* NVLink-C2C
+* NV-CLink
+* NV-DLink
+
+PMU Driver
+----------
+
+The PMU driver describes the available events and configuration of each PMU in
+sysfs. Please see the sections below to get the sysfs path of each PMU. Like
+other uncore PMU drivers, the driver provides "cpumask" sysfs attribute to show
+the CPU id used to handle the PMU event. There is also "associated_cpus"
+sysfs attribute, which contains a list of CPUs associated with the PMU instance.
+
+UCF PMU
+-------
+
+The Unified Coherence Fabric (UCF) in the NVIDIA Tegra410 SoC serves as a
+distributed cache, last level for CPU Memory and CXL Memory, and cache coherent
+interconnect that supports hardware coherence across multiple coherently caching
+agents, including:
+
+ * CPU clusters
+ * GPU
+ * PCIe Ordering Controller Unit (OCU)
+ * Other IO-coherent requesters
+
+The events and configuration options of this PMU device are described in sysfs,
+see /sys/bus/event_source/devices/nvidia_ucf_pmu_<socket-id>.
+
+Some of the events available in this PMU can be used to measure bandwidth and
+utilization:
+
+ * slc_access_rd: count the number of read requests to SLC.
+ * slc_access_wr: count the number of write requests to SLC.
+ * slc_bytes_rd: count the number of bytes transferred by slc_access_rd.
+ * slc_bytes_wr: count the number of bytes transferred by slc_access_wr.
+ * mem_access_rd: count the number of read requests to local or remote memory.
+ * mem_access_wr: count the number of write requests to local or remote memory.
+ * mem_bytes_rd: count the number of bytes transferred by mem_access_rd.
+ * mem_bytes_wr: count the number of bytes transferred by mem_access_wr.
+ * cycles: counts the UCF cycles.
+
+The average bandwidth is calculated as::
+
+ AVG_SLC_READ_BANDWIDTH_IN_GBPS = SLC_BYTES_RD / ELAPSED_TIME_IN_NS
+ AVG_SLC_WRITE_BANDWIDTH_IN_GBPS = SLC_BYTES_WR / ELAPSED_TIME_IN_NS
+ AVG_MEM_READ_BANDWIDTH_IN_GBPS = MEM_BYTES_RD / ELAPSED_TIME_IN_NS
+ AVG_MEM_WRITE_BANDWIDTH_IN_GBPS = MEM_BYTES_WR / ELAPSED_TIME_IN_NS
+
+The average request rate is calculated as::
+
+ AVG_SLC_READ_REQUEST_RATE = SLC_ACCESS_RD / CYCLES
+ AVG_SLC_WRITE_REQUEST_RATE = SLC_ACCESS_WR / CYCLES
+ AVG_MEM_READ_REQUEST_RATE = MEM_ACCESS_RD / CYCLES
+ AVG_MEM_WRITE_REQUEST_RATE = MEM_ACCESS_WR / CYCLES
+
+More details about what other events are available can be found in Tegra410 SoC
+technical reference manual.
+
+The events can be filtered based on source or destination. The source filter
+indicates the traffic initiator to the SLC, e.g local CPU, non-CPU device, or
+remote socket. The destination filter specifies the destination memory type,
+e.g. local system memory (CMEM), local GPU memory (GMEM), or remote memory. The
+local/remote classification of the destination filter is based on the home
+socket of the address, not where the data actually resides. The available
+filters are described in
+/sys/bus/event_source/devices/nvidia_ucf_pmu_<socket-id>/format/.
+
+The list of UCF PMU event filters:
+
+* Source filter:
+
+ * src_loc_cpu: if set, count events from local CPU
+ * src_loc_noncpu: if set, count events from local non-CPU device
+ * src_rem: if set, count events from CPU, GPU, PCIE devices of remote socket
+
+* Destination filter:
+
+ * dst_loc_cmem: if set, count events to local system memory (CMEM) address
+ * dst_loc_gmem: if set, count events to local GPU memory (GMEM) address
+ * dst_loc_other: if set, count events to local CXL memory address
+ * dst_rem: if set, count events to CPU, GPU, and CXL memory address of remote socket
+
+If the source is not specified, the PMU will count events from all sources. If
+the destination is not specified, the PMU will count events to all destinations.
+
+Example usage:
+
+* Count event id 0x0 in socket 0 from all sources and to all destinations::
+
+ perf stat -a -e nvidia_ucf_pmu_0/event=0x0/
+
+* Count event id 0x0 in socket 0 with source filter = local CPU and destination
+ filter = local system memory (CMEM)::
+
+ perf stat -a -e nvidia_ucf_pmu_0/event=0x0,src_loc_cpu=0x1,dst_loc_cmem=0x1/
+
+* Count event id 0x0 in socket 1 with source filter = local non-CPU device and
+ destination filter = remote memory::
+
+ perf stat -a -e nvidia_ucf_pmu_1/event=0x0,src_loc_noncpu=0x1,dst_rem=0x1/
+
+PCIE PMU
+--------
+
+This PMU is located in the SOC fabric connecting the PCIE root complex (RC) and
+the memory subsystem. It monitors all read/write traffic from the root port(s)
+or a particular BDF in a PCIE RC to local or remote memory. There is one PMU per
+PCIE RC in the SoC. Each RC can have up to 16 lanes that can be bifurcated into
+up to 8 root ports. The traffic from each root port can be filtered using RP or
+BDF filter. For example, specifying "src_rp_mask=0xFF" means the PMU counter will
+capture traffic from all RPs. Please see below for more details.
+
+The events and configuration options of this PMU device are described in sysfs,
+see /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>_rc_<pcie-rc-id>.
+
+The events in this PMU can be used to measure bandwidth, utilization, and
+latency:
+
+ * rd_req: count the number of read requests by PCIE device.
+ * wr_req: count the number of write requests by PCIE device.
+ * rd_bytes: count the number of bytes transferred by rd_req.
+ * wr_bytes: count the number of bytes transferred by wr_req.
+ * rd_cum_outs: count outstanding rd_req each cycle.
+ * cycles: count the clock cycles of SOC fabric connected to the PCIE interface.
+
+The average bandwidth is calculated as::
+
+ AVG_RD_BANDWIDTH_IN_GBPS = RD_BYTES / ELAPSED_TIME_IN_NS
+ AVG_WR_BANDWIDTH_IN_GBPS = WR_BYTES / ELAPSED_TIME_IN_NS
+
+The average request rate is calculated as::
+
+ AVG_RD_REQUEST_RATE = RD_REQ / CYCLES
+ AVG_WR_REQUEST_RATE = WR_REQ / CYCLES
+
+
+The average latency is calculated as::
+
+ FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
+ AVG_LATENCY_IN_CYCLES = RD_CUM_OUTS / RD_REQ
+ AVERAGE_LATENCY_IN_NS = AVG_LATENCY_IN_CYCLES / FREQ_IN_GHZ
+
+The PMU events can be filtered based on the traffic source and destination.
+The source filter indicates the PCIE devices that will be monitored. The
+destination filter specifies the destination memory type, e.g. local system
+memory (CMEM), local GPU memory (GMEM), or remote memory. The local/remote
+classification of the destination filter is based on the home socket of the
+address, not where the data actually resides. These filters can be found in
+/sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>_rc_<pcie-rc-id>/format/.
+
+The list of event filters:
+
+* Source filter:
+
+ * src_rp_mask: bitmask of root ports that will be monitored. Each bit in this
+ bitmask represents the RP index in the RC. If the bit is set, all devices under
+ the associated RP will be monitored. E.g "src_rp_mask=0xF" will monitor
+ devices in root port 0 to 3.
+ * src_bdf: the BDF that will be monitored. This is a 16-bit value that
+ follows formula: (bus << 8) + (device << 3) + (function). For example, the
+ value of BDF 27:01.1 is 0x2781.
+ * src_bdf_en: enable the BDF filter. If this is set, the BDF filter value in
+ "src_bdf" is used to filter the traffic.
+
+ Note that Root-Port and BDF filters are mutually exclusive and the PMU in
+ each RC can only have one BDF filter for the whole counters. If BDF filter
+ is enabled, the BDF filter value will be applied to all events.
+
+* Destination filter:
+
+ * dst_loc_cmem: if set, count events to local system memory (CMEM) address
+ * dst_loc_gmem: if set, count events to local GPU memory (GMEM) address
+ * dst_loc_pcie_p2p: if set, count events to local PCIE peer address
+ * dst_loc_pcie_cxl: if set, count events to local CXL memory address
+ * dst_rem: if set, count events to remote memory address
+
+If the source filter is not specified, the PMU will count events from all root
+ports. If the destination filter is not specified, the PMU will count events
+to all destinations.
+
+Example usage:
+
+* Count event id 0x0 from root port 0 of PCIE RC-0 on socket 0 targeting all
+ destinations::
+
+ perf stat -a -e nvidia_pcie_pmu_0_rc_0/event=0x0,src_rp_mask=0x1/
+
+* Count event id 0x1 from root port 0 and 1 of PCIE RC-1 on socket 0 and
+ targeting just local CMEM of socket 0::
+
+ perf stat -a -e nvidia_pcie_pmu_0_rc_1/event=0x1,src_rp_mask=0x3,dst_loc_cmem=0x1/
+
+* Count event id 0x2 from root port 0 of PCIE RC-2 on socket 1 targeting all
+ destinations::
+
+ perf stat -a -e nvidia_pcie_pmu_1_rc_2/event=0x2,src_rp_mask=0x1/
+
+* Count event id 0x3 from root port 0 and 1 of PCIE RC-3 on socket 1 and
+ targeting just local CMEM of socket 1::
+
+ perf stat -a -e nvidia_pcie_pmu_1_rc_3/event=0x3,src_rp_mask=0x3,dst_loc_cmem=0x1/
+
+* Count event id 0x4 from BDF 01:01.0 of PCIE RC-4 on socket 0 targeting all
+ destinations::
+
+ perf stat -a -e nvidia_pcie_pmu_0_rc_4/event=0x4,src_bdf=0x0180,src_bdf_en=0x1/
+
+.. _NVIDIA_T410_PCIE_PMU_RC_Mapping_Section:
+
+Mapping the RC# to lspci segment number
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+Mapping the RC# to lspci segment number can be non-trivial; hence a new NVIDIA
+Designated Vendor Specific Capability (DVSEC) register is added into the PCIE config space
+for each RP. This DVSEC has vendor id "10de" and DVSEC id of "0x4". The DVSEC register
+contains the following information to map PCIE devices under the RP back to its RC# :
+
+ - Bus# (byte 0xc) : bus number as reported by the lspci output
+ - Segment# (byte 0xd) : segment number as reported by the lspci output
+ - RP# (byte 0xe) : port number as reported by LnkCap attribute from lspci for a device with Root Port capability
+ - RC# (byte 0xf): root complex number associated with the RP
+ - Socket# (byte 0x10): socket number associated with the RP
+
+Example script for mapping lspci BDF to RC# and socket#::
+
+ #!/bin/bash
+ while read bdf rest; do
+ dvsec4_reg=$(lspci -vv -s $bdf | awk '
+ /Designated Vendor-Specific: Vendor=10de ID=0004/ {
+ match($0, /\[([0-9a-fA-F]+)/, arr);
+ print "0x" arr[1];
+ exit
+ }
+ ')
+ if [ -n "$dvsec4_reg" ]; then
+ bus=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xc))).b)
+ segment=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xd))).b)
+ rp=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xe))).b)
+ rc=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xf))).b)
+ socket=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0x10))).b)
+ echo "$bdf: Bus=$bus, Segment=$segment, RP=$rp, RC=$rc, Socket=$socket"
+ fi
+ done < <(lspci -d 10de:)
+
+Example output::
+
+ 0001:00:00.0: Bus=00, Segment=01, RP=00, RC=00, Socket=00
+ 0002:80:00.0: Bus=80, Segment=02, RP=01, RC=01, Socket=00
+ 0002:a0:00.0: Bus=a0, Segment=02, RP=02, RC=01, Socket=00
+ 0002:c0:00.0: Bus=c0, Segment=02, RP=03, RC=01, Socket=00
+ 0002:e0:00.0: Bus=e0, Segment=02, RP=04, RC=01, Socket=00
+ 0003:00:00.0: Bus=00, Segment=03, RP=00, RC=02, Socket=00
+ 0004:00:00.0: Bus=00, Segment=04, RP=00, RC=03, Socket=00
+ 0005:00:00.0: Bus=00, Segment=05, RP=00, RC=04, Socket=00
+ 0005:40:00.0: Bus=40, Segment=05, RP=01, RC=04, Socket=00
+ 0005:c0:00.0: Bus=c0, Segment=05, RP=02, RC=04, Socket=00
+ 0006:00:00.0: Bus=00, Segment=06, RP=00, RC=05, Socket=00
+ 0009:00:00.0: Bus=00, Segment=09, RP=00, RC=00, Socket=01
+ 000a:80:00.0: Bus=80, Segment=0a, RP=01, RC=01, Socket=01
+ 000a:a0:00.0: Bus=a0, Segment=0a, RP=02, RC=01, Socket=01
+ 000a:e0:00.0: Bus=e0, Segment=0a, RP=03, RC=01, Socket=01
+ 000b:00:00.0: Bus=00, Segment=0b, RP=00, RC=02, Socket=01
+ 000c:00:00.0: Bus=00, Segment=0c, RP=00, RC=03, Socket=01
+ 000d:00:00.0: Bus=00, Segment=0d, RP=00, RC=04, Socket=01
+ 000d:40:00.0: Bus=40, Segment=0d, RP=01, RC=04, Socket=01
+ 000d:c0:00.0: Bus=c0, Segment=0d, RP=02, RC=04, Socket=01
+ 000e:00:00.0: Bus=00, Segment=0e, RP=00, RC=05, Socket=01
+
+PCIE-TGT PMU
+------------
+
+This PMU is located in the SOC fabric connecting the PCIE root complex (RC) and
+the memory subsystem. It monitors traffic targeting PCIE BAR and CXL HDM ranges.
+There is one PCIE-TGT PMU per PCIE RC in the SoC. Each RC in Tegra410 SoC can
+have up to 16 lanes that can be bifurcated into up to 8 root ports (RP). The PMU
+provides RP filter to count PCIE BAR traffic to each RP and address filter to
+count access to PCIE BAR or CXL HDM ranges. The details of the filters are
+described in the following sections.
+
+Mapping the RC# to lspci segment number is similar to the PCIE PMU. Please see
+:ref:`NVIDIA_T410_PCIE_PMU_RC_Mapping_Section` for more info.
+
+The events and configuration options of this PMU device are available in sysfs,
+see /sys/bus/event_source/devices/nvidia_pcie_tgt_pmu_<socket-id>_rc_<pcie-rc-id>.
+
+The events in this PMU can be used to measure bandwidth and utilization:
+
+ * rd_req: count the number of read requests to PCIE.
+ * wr_req: count the number of write requests to PCIE.
+ * rd_bytes: count the number of bytes transferred by rd_req.
+ * wr_bytes: count the number of bytes transferred by wr_req.
+ * cycles: count the clock cycles of SOC fabric connected to the PCIE interface.
+
+The average bandwidth is calculated as::
+
+ AVG_RD_BANDWIDTH_IN_GBPS = RD_BYTES / ELAPSED_TIME_IN_NS
+ AVG_WR_BANDWIDTH_IN_GBPS = WR_BYTES / ELAPSED_TIME_IN_NS
+
+The average request rate is calculated as::
+
+ AVG_RD_REQUEST_RATE = RD_REQ / CYCLES
+ AVG_WR_REQUEST_RATE = WR_REQ / CYCLES
+
+The PMU events can be filtered based on the destination root port or target
+address range. Filtering based on RP is only available for PCIE BAR traffic.
+Address filter works for both PCIE BAR and CXL HDM ranges. These filters can be
+found in sysfs, see
+/sys/bus/event_source/devices/nvidia_pcie_tgt_pmu_<socket-id>_rc_<pcie-rc-id>/format/.
+
+Destination filter settings:
+
+* dst_rp_mask: bitmask to select the root port(s) to monitor. E.g. "dst_rp_mask=0xFF"
+ corresponds to all root ports (from 0 to 7) in the PCIE RC. Note that this filter is
+ only available for PCIE BAR traffic.
+* dst_addr_base: BAR or CXL HDM filter base address.
+* dst_addr_mask: BAR or CXL HDM filter address mask.
+* dst_addr_en: enable BAR or CXL HDM address range filter. If this is set, the
+ address range specified by "dst_addr_base" and "dst_addr_mask" will be used to filter
+ the PCIE BAR and CXL HDM traffic address. The PMU uses the following comparison
+ to determine if the traffic destination address falls within the filter range::
+
+ (txn's addr & dst_addr_mask) == (dst_addr_base & dst_addr_mask)
+
+ If the comparison succeeds, then the event will be counted.
+
+If the destination filter is not specified, the RP filter will be configured by default
+to count PCIE BAR traffic to all root ports.
+
+Example usage:
+
+* Count event id 0x0 to root port 0 and 1 of PCIE RC-0 on socket 0::
+
+ perf stat -a -e nvidia_pcie_tgt_pmu_0_rc_0/event=0x0,dst_rp_mask=0x3/
+
+* Count event id 0x1 for accesses to PCIE BAR or CXL HDM address range
+ 0x10000 to 0x100FF on socket 0's PCIE RC-1::
+
+ perf stat -a -e nvidia_pcie_tgt_pmu_0_rc_1/event=0x1,dst_addr_base=0x10000,dst_addr_mask=0xFFF00,dst_addr_en=0x1/
+
+CPU Memory (CMEM) Latency PMU
+-----------------------------
+
+This PMU monitors latency events of memory read requests from the edge of the
+Unified Coherence Fabric (UCF) to local CPU DRAM:
+
+ * RD_REQ counters: count read requests (32B per request).
+ * RD_CUM_OUTS counters: accumulated outstanding request counter, which track
+ how many cycles the read requests are in flight.
+ * CYCLES counter: counts the number of elapsed cycles.
+
+The average latency is calculated as::
+
+ FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
+ AVG_LATENCY_IN_CYCLES = RD_CUM_OUTS / RD_REQ
+ AVERAGE_LATENCY_IN_NS = AVG_LATENCY_IN_CYCLES / FREQ_IN_GHZ
+
+The events and configuration options of this PMU device are described in sysfs,
+see /sys/bus/event_source/devices/nvidia_cmem_latency_pmu_<socket-id>.
+
+Example usage::
+
+ perf stat -a -e '{nvidia_cmem_latency_pmu_0/rd_req/,nvidia_cmem_latency_pmu_0/rd_cum_outs/,nvidia_cmem_latency_pmu_0/cycles/}'
+
+NVLink-C2C PMU
+--------------
+
+This PMU monitors latency events of memory read/write requests that pass through
+the NVIDIA Chip-to-Chip (C2C) interface. Bandwidth events are not available
+in this PMU, unlike the C2C PMU in Grace (Tegra241 SoC).
+
+The events and configuration options of this PMU device are available in sysfs,
+see /sys/bus/event_source/devices/nvidia_nvlink_c2c_pmu_<socket-id>.
+
+The list of events:
+
+ * IN_RD_CUM_OUTS: accumulated outstanding request (in cycles) of incoming read requests.
+ * IN_RD_REQ: the number of incoming read requests.
+ * IN_WR_CUM_OUTS: accumulated outstanding request (in cycles) of incoming write requests.
+ * IN_WR_REQ: the number of incoming write requests.
+ * OUT_RD_CUM_OUTS: accumulated outstanding request (in cycles) of outgoing read requests.
+ * OUT_RD_REQ: the number of outgoing read requests.
+ * OUT_WR_CUM_OUTS: accumulated outstanding request (in cycles) of outgoing write requests.
+ * OUT_WR_REQ: the number of outgoing write requests.
+ * CYCLES: NVLink-C2C interface cycle counts.
+
+The incoming events count the reads/writes from remote device to the SoC.
+The outgoing events count the reads/writes from the SoC to remote device.
+
+The sysfs /sys/bus/event_source/devices/nvidia_nvlink_c2c_pmu_<socket-id>/peer
+contains the information about the connected device.
+
+When the C2C interface is connected to GPU(s), the user can use the
+"gpu_mask" parameter to filter traffic to/from specific GPU(s). Each bit represents the GPU
+index, e.g. "gpu_mask=0x1" corresponds to GPU 0 and "gpu_mask=0x3" is for GPU 0 and 1.
+The PMU will monitor all GPUs by default if not specified.
+
+When connected to another SoC, only the read events are available.
+
+The events can be used to calculate the average latency of the read/write requests::
+
+ C2C_FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
+
+ IN_RD_AVG_LATENCY_IN_CYCLES = IN_RD_CUM_OUTS / IN_RD_REQ
+ IN_RD_AVG_LATENCY_IN_NS = IN_RD_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ
+
+ IN_WR_AVG_LATENCY_IN_CYCLES = IN_WR_CUM_OUTS / IN_WR_REQ
+ IN_WR_AVG_LATENCY_IN_NS = IN_WR_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ
+
+ OUT_RD_AVG_LATENCY_IN_CYCLES = OUT_RD_CUM_OUTS / OUT_RD_REQ
+ OUT_RD_AVG_LATENCY_IN_NS = OUT_RD_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ
+
+ OUT_WR_AVG_LATENCY_IN_CYCLES = OUT_WR_CUM_OUTS / OUT_WR_REQ
+ OUT_WR_AVG_LATENCY_IN_NS = OUT_WR_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ
+
+Example usage:
+
+ * Count incoming traffic from all GPUs connected via NVLink-C2C::
+
+ perf stat -a -e nvidia_nvlink_c2c_pmu_0/in_rd_req/
+
+ * Count incoming traffic from GPU 0 connected via NVLink-C2C::
+
+ perf stat -a -e nvidia_nvlink_c2c_pmu_0/in_rd_cum_outs,gpu_mask=0x1/
+
+ * Count incoming traffic from GPU 1 connected via NVLink-C2C::
+
+ perf stat -a -e nvidia_nvlink_c2c_pmu_0/in_rd_cum_outs,gpu_mask=0x2/
+
+ * Count outgoing traffic to all GPUs connected via NVLink-C2C::
+
+ perf stat -a -e nvidia_nvlink_c2c_pmu_0/out_rd_req/
+
+ * Count outgoing traffic to GPU 0 connected via NVLink-C2C::
+
+ perf stat -a -e nvidia_nvlink_c2c_pmu_0/out_rd_cum_outs,gpu_mask=0x1/
+
+ * Count outgoing traffic to GPU 1 connected via NVLink-C2C::
+
+ perf stat -a -e nvidia_nvlink_c2c_pmu_0/out_rd_cum_outs,gpu_mask=0x2/
+
+NV-CLink PMU
+------------
+
+This PMU monitors latency events of memory read requests that pass through
+the NV-CLINK interface. Bandwidth events are not available in this PMU.
+In Tegra410 SoC, the NV-CLink interface is used to connect to another Tegra410
+SoC and this PMU only counts read traffic.
+
+The events and configuration options of this PMU device are available in sysfs,
+see /sys/bus/event_source/devices/nvidia_nvclink_pmu_<socket-id>.
+
+The list of events:
+
+ * IN_RD_CUM_OUTS: accumulated outstanding request (in cycles) of incoming read requests.
+ * IN_RD_REQ: the number of incoming read requests.
+ * OUT_RD_CUM_OUTS: accumulated outstanding request (in cycles) of outgoing read requests.
+ * OUT_RD_REQ: the number of outgoing read requests.
+ * CYCLES: NV-CLINK interface cycle counts.
+
+The incoming events count the reads from remote device to the SoC.
+The outgoing events count the reads from the SoC to remote device.
+
+The events can be used to calculate the average latency of the read requests::
+
+ CLINK_FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
+
+ IN_RD_AVG_LATENCY_IN_CYCLES = IN_RD_CUM_OUTS / IN_RD_REQ
+ IN_RD_AVG_LATENCY_IN_NS = IN_RD_AVG_LATENCY_IN_CYCLES / CLINK_FREQ_IN_GHZ
+
+ OUT_RD_AVG_LATENCY_IN_CYCLES = OUT_RD_CUM_OUTS / OUT_RD_REQ
+ OUT_RD_AVG_LATENCY_IN_NS = OUT_RD_AVG_LATENCY_IN_CYCLES / CLINK_FREQ_IN_GHZ
+
+Example usage:
+
+ * Count incoming read traffic from remote SoC connected via NV-CLINK::
+
+ perf stat -a -e nvidia_nvclink_pmu_0/in_rd_req/
+
+ * Count outgoing read traffic to remote SoC connected via NV-CLINK::
+
+ perf stat -a -e nvidia_nvclink_pmu_0/out_rd_req/
+
+NV-DLink PMU
+------------
+
+This PMU monitors latency events of memory read requests that pass through
+the NV-DLINK interface. Bandwidth events are not available in this PMU.
+In Tegra410 SoC, this PMU only counts CXL memory read traffic.
+
+The events and configuration options of this PMU device are available in sysfs,
+see /sys/bus/event_source/devices/nvidia_nvdlink_pmu_<socket-id>.
+
+The list of events:
+
+ * IN_RD_CUM_OUTS: accumulated outstanding read requests (in cycles) to CXL memory.
+ * IN_RD_REQ: the number of read requests to CXL memory.
+ * CYCLES: NV-DLINK interface cycle counts.
+
+The events can be used to calculate the average latency of the read requests::
+
+ DLINK_FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
+
+ IN_RD_AVG_LATENCY_IN_CYCLES = IN_RD_CUM_OUTS / IN_RD_REQ
+ IN_RD_AVG_LATENCY_IN_NS = IN_RD_AVG_LATENCY_IN_CYCLES / DLINK_FREQ_IN_GHZ
+
+Example usage:
+
+ * Count read events to CXL memory::
+
+ perf stat -a -e '{nvidia_nvdlink_pmu_0/in_rd_req/,nvidia_nvdlink_pmu_0/in_rd_cum_outs/}'
diff --git a/Documentation/admin-guide/perf/qcom_l2_pmu.rst b/Documentation/admin-guide/perf/qcom_l2_pmu.rst
new file mode 100644
index 000000000..c37c6be9b
--- /dev/null
+++ b/Documentation/admin-guide/perf/qcom_l2_pmu.rst
@@ -0,0 +1,39 @@
+=====================================================================
+Qualcomm Technologies Level-2 Cache Performance Monitoring Unit (PMU)
+=====================================================================
+
+This driver supports the L2 cache clusters found in Qualcomm Technologies
+Centriq SoCs. There are multiple physical L2 cache clusters, each with their
+own PMU. Each cluster has one or more CPUs associated with it.
+
+There is one logical L2 PMU exposed, which aggregates the results from
+the physical PMUs.
+
+The driver provides a description of its available events and configuration
+options in sysfs, see /sys/bus/event_source/devices/l2cache_0.
+
+The "format" directory describes the format of the events.
+
+Events can be envisioned as a 2-dimensional array. Each column represents
+a group of events. There are 8 groups. Only one entry from each
+group can be in use at a time. If multiple events from the same group
+are specified, the conflicting events cannot be counted at the same time.
+
+Events are specified as 0xCCG, where CC is 2 hex digits specifying
+the code (array row) and G specifies the group (column) 0-7.
+
+In addition there is a cycle counter event specified by the value 0xFE
+which is outside the above scheme.
+
+The driver provides a "cpumask" sysfs attribute which contains a mask
+consisting of one CPU per cluster which will be used to handle all the PMU
+events on that cluster.
+
+Examples for use with perf::
+
+ perf stat -e l2cache_0/config=0x001/,l2cache_0/config=0x042/ -a sleep 1
+
+ perf stat -e l2cache_0/config=0xfe/ -C 2 sleep 1
+
+The driver does not support sampling, therefore "perf record" will
+not work. Per-task perf sessions are not supported.
diff --git a/Documentation/admin-guide/perf/qcom_l3_pmu.rst b/Documentation/admin-guide/perf/qcom_l3_pmu.rst
new file mode 100644
index 000000000..a66556b7e
--- /dev/null
+++ b/Documentation/admin-guide/perf/qcom_l3_pmu.rst
@@ -0,0 +1,26 @@
+===========================================================================
+Qualcomm Datacenter Technologies L3 Cache Performance Monitoring Unit (PMU)
+===========================================================================
+
+This driver supports the L3 cache PMUs found in Qualcomm Datacenter Technologies
+Centriq SoCs. The L3 cache on these SOCs is composed of multiple slices, shared
+by all cores within a socket. Each slice is exposed as a separate uncore perf
+PMU with device name l3cache_<socket>_<instance>. User space is responsible
+for aggregating across slices.
+
+The driver provides a description of its available events and configuration
+options in sysfs, see /sys/bus/event_source/devices/l3cache*. Given that these are uncore PMUs
+the driver also exposes a "cpumask" sysfs attribute which contains a mask
+consisting of one CPU per socket which will be used to handle all the PMU
+events on that socket.
+
+The hardware implements 32bit event counters and has a flat 8bit event space
+exposed via the "event" format attribute. In addition to the 32bit physical
+counters the driver supports virtual 64bit hardware counters by using hardware
+counter chaining. This feature is exposed via the "lc" (long counter) format
+flag. E.g.::
+
+ perf stat -e l3cache_0_0/read-miss,lc/
+
+Given that these are uncore PMUs the driver does not support sampling, therefore
+"perf record" will not work. Per-task perf sessions are not supported.
diff --git a/Documentation/admin-guide/perf/starfive_starlink_pmu.rst b/Documentation/admin-guide/perf/starfive_starlink_pmu.rst
new file mode 100644
index 000000000..2932ddb4e
--- /dev/null
+++ b/Documentation/admin-guide/perf/starfive_starlink_pmu.rst
@@ -0,0 +1,46 @@
+================================================
+StarFive StarLink Performance Monitor Unit (PMU)
+================================================
+
+StarFive StarLink Performance Monitor Unit (PMU) exists within the
+StarLink Coherent Network on Chip (CNoC) that connects multiple CPU
+clusters with an L3 memory system.
+
+The uncore PMU supports overflow interrupt, up to 16 programmable 64bit
+event counters, and an independent 64bit cycle counter.
+The PMU can only be accessed via Memory Mapped I/O and are common to the
+cores connected to the same PMU.
+
+Driver exposes supported PMU events in sysfs "events" directory under::
+
+ /sys/bus/event_source/devices/starfive_starlink_pmu/events/
+
+Driver exposes cpu used to handle PMU events in sysfs "cpumask" directory
+under::
+
+ /sys/bus/event_source/devices/starfive_starlink_pmu/cpumask/
+
+Driver describes the format of config (event ID) in sysfs "format" directory
+under::
+
+ /sys/bus/event_source/devices/starfive_starlink_pmu/format/
+
+Example of perf usage::
+
+ $ perf list
+
+ starfive_starlink_pmu/cycles/ [Kernel PMU event]
+ starfive_starlink_pmu/read_hit/ [Kernel PMU event]
+ starfive_starlink_pmu/read_miss/ [Kernel PMU event]
+ starfive_starlink_pmu/read_request/ [Kernel PMU event]
+ starfive_starlink_pmu/release_request/ [Kernel PMU event]
+ starfive_starlink_pmu/write_hit/ [Kernel PMU event]
+ starfive_starlink_pmu/write_miss/ [Kernel PMU event]
+ starfive_starlink_pmu/write_request/ [Kernel PMU event]
+ starfive_starlink_pmu/writeback/ [Kernel PMU event]
+
+
+ $ perf stat -a -e /starfive_starlink_pmu/cycles/ sleep 1
+
+Sampling is not supported. As a result, "perf record" is not supported.
+Attaching to a task is not supported, only system-wide counting is supported.
diff --git a/Documentation/admin-guide/perf/thunderx2-pmu.rst b/Documentation/admin-guide/perf/thunderx2-pmu.rst
new file mode 100644
index 000000000..9255f7bf9
--- /dev/null
+++ b/Documentation/admin-guide/perf/thunderx2-pmu.rst
@@ -0,0 +1,44 @@
+=============================================================
+Cavium ThunderX2 SoC Performance Monitoring Unit (PMU UNCORE)
+=============================================================
+
+The ThunderX2 SoC PMU consists of independent, system-wide, per-socket
+PMUs such as the Level 3 Cache (L3C), DDR4 Memory Controller (DMC) and
+Cavium Coherent Processor Interconnect (CCPI2).
+
+The DMC has 8 interleaved channels and the L3C has 16 interleaved tiles.
+Events are counted for the default channel (i.e. channel 0) and prorated
+to the total number of channels/tiles.
+
+The DMC and L3C support up to 4 counters, while the CCPI2 supports up to 8
+counters. Counters are independently programmable to different events and
+can be started and stopped individually. None of the counters support an
+overflow interrupt. DMC and L3C counters are 32-bit and read every 2 seconds.
+The CCPI2 counters are 64-bit and assumed not to overflow in normal operation.
+
+PMU UNCORE (perf) driver:
+
+The thunderx2_pmu driver registers per-socket perf PMUs for the DMC and
+L3C devices. Each PMU can be used to count up to 4 (DMC/L3C) or up to 8
+(CCPI2) events simultaneously. The PMUs provide a description of their
+available events and configuration options under sysfs, see
+/sys/bus/event_source/devices/uncore_<l3c_S/dmc_S/ccpi2_S/>; S is the socket id.
+
+The driver does not support sampling, therefore "perf record" will not
+work. Per-task perf sessions are also not supported.
+
+Examples::
+
+ # perf stat -a -e uncore_dmc_0/cnt_cycles/ sleep 1
+
+ # perf stat -a -e \
+ uncore_dmc_0/cnt_cycles/,\
+ uncore_dmc_0/data_transfers/,\
+ uncore_dmc_0/read_txns/,\
+ uncore_dmc_0/write_txns/ sleep 1
+
+ # perf stat -a -e \
+ uncore_l3c_0/read_request/,\
+ uncore_l3c_0/read_hit/,\
+ uncore_l3c_0/inv_request/,\
+ uncore_l3c_0/inv_hit/ sleep 1
diff --git a/Documentation/admin-guide/perf/xgene-pmu.rst b/Documentation/admin-guide/perf/xgene-pmu.rst
new file mode 100644
index 000000000..98ccb8e77
--- /dev/null
+++ b/Documentation/admin-guide/perf/xgene-pmu.rst
@@ -0,0 +1,49 @@
+================================================
+APM X-Gene SoC Performance Monitoring Unit (PMU)
+================================================
+
+X-Gene SoC PMU consists of various independent system device PMUs such as
+L3 cache(s), I/O bridge(s), memory controller bridge(s) and memory
+controller(s). These PMU devices are loosely architected to follow the
+same model as the PMU for ARM cores. The PMUs share the same top level
+interrupt and status CSR region.
+
+PMU (perf) driver
+-----------------
+
+The xgene-pmu driver registers several perf PMU drivers. Each of the perf
+driver provides description of its available events and configuration options
+in sysfs, see /sys/bus/event_source/devices/<l3cX/iobX/mcbX/mcX>/.
+
+The "format" directory describes format of the config (event ID),
+config1 (agent ID) fields of the perf_event_attr structure. The "events"
+directory provides configuration templates for all supported event types that
+can be used with perf tool. For example, "l3c0/bank-fifo-full/" is an
+equivalent of "l3c0/config=0x0b/".
+
+Most of the SoC PMU has a specific list of agent ID used for monitoring
+performance of a specific datapath. For example, agents of a L3 cache can be
+a specific CPU or an I/O bridge. Each PMU has a set of 2 registers capable of
+masking the agents from which the request come from. If the bit with
+the bit number corresponding to the agent is set, the event is counted only if
+it is caused by a request from that agent. Each agent ID bit is inversely mapped
+to a corresponding bit in "config1" field. By default, the event will be
+counted for all agent requests (config1 = 0x0). For all the supported agents of
+each PMU, please refer to APM X-Gene User Manual.
+
+Each perf driver also provides a "cpumask" sysfs attribute, which contains a
+single CPU ID of the processor which will be used to handle all the PMU events.
+
+Example for perf tool use::
+
+ / # perf list | grep -e l3c -e iob -e mcb -e mc
+ l3c0/ackq-full/ [Kernel PMU event]
+ <...>
+ mcb1/mcb-csw-stall/ [Kernel PMU event]
+
+ / # perf stat -a -e l3c0/read-miss/,mcb1/csw-write-request/ sleep 1
+
+ / # perf stat -a -e l3c0/read-miss,config1=0xfffffffffffffffe/ sleep 1
+
+The driver does not support sampling, therefore "perf record" will
+not work. Per-task (without "-a") perf sessions are not supported.