iio: proximity: vl53l0x-i2c: claim direct mode for raw readsgrafted
vl53l0x_read_raw() starts a single-shot ranging measurement and reads back the result. Once the triggered buffer is enabled the sensor runs in continuous mode and its data-ready interrupt is routed to the trigger, so a concurrent in_distance_raw read disturbs the streaming setup and never gets its completion, returning -ETIMEDOUT. The original submission claimed direct mode here, but it was dropped during review because the driver had no buffer support at the time [1]. Continuous (buffered) mode was later added without restoring the claim [2], reintroducing the conflict. Reject direct reads while buffered capture is active by claiming direct mode around the measurement, as the vl53l1x sibling already does. Fixes: 762186c6e7b1 ("iio: proximity: vl53l0x-i2c: Added continuous mode support") Link: https://lore.kernel.org/linux-iio/20180911160300.GA9212@himanshu-Vostro-3559/ [1] Link: https://lore.kernel.org/linux-iio/20240909101508.263085-3-abhashkumarjha123@gmail.com/ [2] Signed-off-by: Donggeun Yoo <donggeunyoo.kernel@gmail.com> Cc: stable@vger.kernel.org Signed-off-by: Jonathan Cameron <jonathan.cameron@oss.qualcomm.com>
Diffstat (limited to 'Documentation/PCI/endpoint/function')
-rw-r--r--Documentation/PCI/endpoint/function/binding/pci-ntb.rst38
-rw-r--r--Documentation/PCI/endpoint/function/binding/pci-test.rst26
2 files changed, 64 insertions, 0 deletions
diff --git a/Documentation/PCI/endpoint/function/binding/pci-ntb.rst b/Documentation/PCI/endpoint/function/binding/pci-ntb.rst
new file mode 100644
index 000000000..40253d3d5
--- /dev/null
+++ b/Documentation/PCI/endpoint/function/binding/pci-ntb.rst
@@ -0,0 +1,38 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+==========================
+PCI NTB Endpoint Function
+==========================
+
+1) Create a subdirectory to pci_epf_ntb directory in configfs.
+
+Standard EPF Configurable Fields:
+
+================ ===========================================================
+vendorid should be 0x104c
+deviceid should be 0xb00d for TI's J721E SoC
+revid don't care
+progif_code don't care
+subclass_code should be 0x00
+baseclass_code should be 0x5
+cache_line_size don't care
+subsys_vendor_id don't care
+subsys_id don't care
+interrupt_pin don't care
+msi_interrupts don't care
+msix_interrupts don't care
+================ ===========================================================
+
+2) Create a subdirectory to directory created in 1
+
+NTB EPF specific configurable fields:
+
+================ ===========================================================
+db_count Number of doorbells; default = 4
+mw1 size of memory window1
+mw2 size of memory window2
+mw3 size of memory window3
+mw4 size of memory window4
+num_mws Number of memory windows; max = 4
+spad_count Number of scratchpad registers; default = 64
+================ ===========================================================
diff --git a/Documentation/PCI/endpoint/function/binding/pci-test.rst b/Documentation/PCI/endpoint/function/binding/pci-test.rst
new file mode 100644
index 000000000..57ee866fb
--- /dev/null
+++ b/Documentation/PCI/endpoint/function/binding/pci-test.rst
@@ -0,0 +1,26 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+==========================
+PCI Test Endpoint Function
+==========================
+
+name: Should be "pci_epf_test" to bind to the pci_epf_test driver.
+
+Configurable Fields:
+
+================ ===========================================================
+vendorid should be 0x104c
+deviceid should be 0xb500 for DRA74x and 0xb501 for DRA72x
+revid don't care
+progif_code don't care
+subclass_code don't care
+baseclass_code should be 0xff
+cache_line_size don't care
+subsys_vendor_id don't care
+subsys_id don't care
+interrupt_pin Should be 1 - INTA, 2 - INTB, 3 - INTC, 4 -INTD
+msi_interrupts Should be 1 to 32 depending on the number of MSI interrupts
+ to test
+msix_interrupts Should be 1 to 2048 depending on the number of MSI-X
+ interrupts to test
+================ ===========================================================