summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-devices-mapping
diff options
context:
space:
mode:
authorSven Schnelle <svens@linux.ibm.com>2026-09-09 11:29:53 +0200
committerMasami Hiramatsu (Google) <mhiramat@kernel.org>2026-09-10 08:43:35 +0900
commitd22c3e0088e85be8131f7a9283f759cdbb20726d (patch)
tree9668df2aa27b26f850d3ba5ba1287e443803675c /Documentation/ABI/testing/sysfs-devices-mapping
downloadlinux-stable-d22c3e0088e85be8131f7a9283f759cdbb20726d.tar.gz
linux-stable-d22c3e0088e85be8131f7a9283f759cdbb20726d.zip
selftests/ftrace: Fix unique symbol check in kprobe_non_uniq_symbol.tcgrafted
The current regex also matches symbols in modules, which makes the test fail on s390 where name_show is present only once in the kernel, but also multiple times in modules: 000001b1401cdc20 t name_show 000001b0c05e6c40 t name_show [mdev] 000001b0c0495f30 t name_show [i2c_core] Fix this by changing the regular expression to only match the function name. Link: https://lore.kernel.org/all/20260909092954.2200558-1-svens@linux.ibm.com/ Fixes: 03b80ff8023a ("selftests/ftrace: Add new test case which checks non unique symbol") Signed-off-by: Sven Schnelle <svens@linux.ibm.com> Reviewed-by: Steven Rostedt <rostedt@goodmis.org> Signed-off-by: Masami Hiramatsu (Google) <mhiramat@kernel.org>
Diffstat (limited to 'Documentation/ABI/testing/sysfs-devices-mapping')
-rw-r--r--Documentation/ABI/testing/sysfs-devices-mapping62
1 files changed, 62 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-devices-mapping b/Documentation/ABI/testing/sysfs-devices-mapping
new file mode 100644
index 000000000..2eee1446a
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-devices-mapping
@@ -0,0 +1,62 @@
+What: /sys/devices/uncore_iio_x/dieX
+Date: February 2020
+Contact: Alexander Antonov <alexander.antonov@linux.intel.com>
+Description:
+ Each IIO stack (PCIe root port) has its own IIO PMON block, so
+ each dieX file (where X is die number) holds "Segment:Root Bus"
+ for PCIe root port, which can be monitored by that IIO PMON
+ block.
+ For example, on 4-die Xeon platform with up to 6 IIO stacks per
+ die and, therefore, 6 IIO PMON blocks per die, the mapping of
+ IIO PMON block 0 exposes as the following::
+
+ $ ls /sys/devices/uncore_iio_0/die*
+ -r--r--r-- /sys/devices/uncore_iio_0/die0
+ -r--r--r-- /sys/devices/uncore_iio_0/die1
+ -r--r--r-- /sys/devices/uncore_iio_0/die2
+ -r--r--r-- /sys/devices/uncore_iio_0/die3
+
+ $ tail /sys/devices/uncore_iio_0/die*
+ ==> /sys/devices/uncore_iio_0/die0 <==
+ 0000:00
+ ==> /sys/devices/uncore_iio_0/die1 <==
+ 0000:40
+ ==> /sys/devices/uncore_iio_0/die2 <==
+ 0000:80
+ ==> /sys/devices/uncore_iio_0/die3 <==
+ 0000:c0
+
+ Which means::
+
+ IIO PMU 0 on die 0 belongs to PCI RP on bus 0x00, domain 0x0000
+ IIO PMU 0 on die 1 belongs to PCI RP on bus 0x40, domain 0x0000
+ IIO PMU 0 on die 2 belongs to PCI RP on bus 0x80, domain 0x0000
+ IIO PMU 0 on die 3 belongs to PCI RP on bus 0xc0, domain 0x0000
+
+What: /sys/devices/uncore_upi_x/dieX
+Date: March 2022
+Contact: Alexander Antonov <alexander.antonov@linux.intel.com>
+Description:
+ Each /sys/devices/uncore_upi_X/dieY file holds "upi_Z,die_W"
+ value that means UPI link number X on die Y is connected to UPI
+ link Z on die W and this link between sockets can be monitored
+ by UPI PMON block.
+ For example, 4-die Sapphire Rapids platform has the following
+ UPI 0 topology::
+
+ # tail /sys/devices/uncore_upi_0/die*
+ ==> /sys/devices/uncore_upi_0/die0 <==
+ upi_1,die_1
+ ==> /sys/devices/uncore_upi_0/die1 <==
+ upi_0,die_3
+ ==> /sys/devices/uncore_upi_0/die2 <==
+ upi_1,die_3
+ ==> /sys/devices/uncore_upi_0/die3 <==
+ upi_0,die_1
+
+ Which means::
+
+ UPI link 0 on die 0 is connected to UPI link 1 on die 1
+ UPI link 0 on die 1 is connected to UPI link 0 on die 3
+ UPI link 0 on die 2 is connected to UPI link 1 on die 3
+ UPI link 0 on die 3 is connected to UPI link 0 on die 1 \ No newline at end of file