diff options
| author | Sean Christopherson <seanjc@google.com> | 2026-09-23 09:37:21 -0700 |
|---|---|---|
| committer | Paolo Bonzini <pbonzini@redhat.com> | 2026-09-26 00:39:55 -0400 |
| commit | 93de2a6a4b91b72607136dd656edf03fb399d27f (patch) | |
| tree | 9220c76eb23cb39a146fac9692ee69afa4aa3135 /Documentation/ABI/testing/sysfs-class-led-trigger-tty | |
| download | linux-stable-93de2a6a4b91b72607136dd656edf03fb399d27f.tar.gz linux-stable-93de2a6a4b91b72607136dd656edf03fb399d27f.zip | |
KVM: SEV: Do cache maintenance on the source VM during intra-host migrationgrafted
Manually perform cache maintenance on the source VM during intra-host
migration to ensure no stale data is left in CPU caches after the VM is
destroyed. Because the source VM is "converted" to a non-SEV VM, KVM's
memory reclaim flows won't trigger cache maintenance, e.g. when all guest
memory is reclaimed in response to detaching from the mmu_notifier.
Note, relying on the destination VM to do cache maintenance isn't an option
as KVM doesn't require identical guest memory configurations, i.e. the
source VM may have access to memory that the destination VM does not.
Enforcing equivalent memory configurations is infeasible, as it would
require a *deep* comparison of memslots, e.g. to verify that not only are
the memslot identical, but what the memslots point at is also identical.
Fixes: b56639318bb2 ("KVM: SEV: Add support for SEV intra host migration")
Cc: stable@vger.kernel.org
Reported-by: Stefan Teodorescu <fane@google.com>
Signed-off-by: Sean Christopherson <seanjc@google.com>
Message-ID: <20260923163721.1584779-3-seanjc@google.com>
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
Diffstat (limited to 'Documentation/ABI/testing/sysfs-class-led-trigger-tty')
| -rw-r--r-- | Documentation/ABI/testing/sysfs-class-led-trigger-tty | 62 |
1 files changed, 62 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-led-trigger-tty b/Documentation/ABI/testing/sysfs-class-led-trigger-tty new file mode 100644 index 000000000..308fbc362 --- /dev/null +++ b/Documentation/ABI/testing/sysfs-class-led-trigger-tty @@ -0,0 +1,62 @@ +What: /sys/class/leds/<tty_led>/ttyname +Date: Dec 2020 +KernelVersion: 5.10 +Contact: linux-leds@vger.kernel.org +Description: + Specifies the tty device name of the triggering tty + +What: /sys/class/leds/<tty_led>/rx +Date: February 2024 +KernelVersion: 6.8 +Description: + Signal reception (rx) of data on the named tty device. + If set to 0, the LED will not blink on reception. + If set to 1 (default), the LED will blink on reception. + +What: /sys/class/leds/<tty_led>/tx +Date: February 2024 +KernelVersion: 6.8 +Description: + Signal transmission (tx) of data on the named tty device. + If set to 0, the LED will not blink on transmission. + If set to 1 (default), the LED will blink on transmission. + +What: /sys/class/leds/<tty_led>/cts +Date: February 2024 +KernelVersion: 6.8 +Description: + CTS = Clear To Send + DCE is ready to accept data from the DTE. + If the line state is detected, the LED is switched on. + If set to 0 (default), the LED will not evaluate CTS. + If set to 1, the LED will evaluate CTS. + +What: /sys/class/leds/<tty_led>/dsr +Date: February 2024 +KernelVersion: 6.8 +Description: + DSR = Data Set Ready + DCE is ready to receive and send data. + If the line state is detected, the LED is switched on. + If set to 0 (default), the LED will not evaluate DSR. + If set to 1, the LED will evaluate DSR. + +What: /sys/class/leds/<tty_led>/dcd +Date: February 2024 +KernelVersion: 6.8 +Description: + DCD = Data Carrier Detect + DTE is receiving a carrier from the DCE. + If the line state is detected, the LED is switched on. + If set to 0 (default), the LED will not evaluate CAR (DCD). + If set to 1, the LED will evaluate CAR (DCD). + +What: /sys/class/leds/<tty_led>/rng +Date: February 2024 +KernelVersion: 6.8 +Description: + RNG = Ring Indicator + DCE has detected an incoming ring signal on the telephone + line. If the line state is detected, the LED is switched on. + If set to 0 (default), the LED will not evaluate RNG. + If set to 1, the LED will evaluate RNG. |