summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-class-led-flash
diff options
context:
space:
mode:
authorSven Schnelle <svens@linux.ibm.com>2026-09-09 11:29:53 +0200
committerMasami Hiramatsu (Google) <mhiramat@kernel.org>2026-09-10 08:43:35 +0900
commitd22c3e0088e85be8131f7a9283f759cdbb20726d (patch)
tree9668df2aa27b26f850d3ba5ba1287e443803675c /Documentation/ABI/testing/sysfs-class-led-flash
downloadlinux-stable-d22c3e0088e85be8131f7a9283f759cdbb20726d.tar.gz
linux-stable-d22c3e0088e85be8131f7a9283f759cdbb20726d.zip
selftests/ftrace: Fix unique symbol check in kprobe_non_uniq_symbol.tcgrafted
The current regex also matches symbols in modules, which makes the test fail on s390 where name_show is present only once in the kernel, but also multiple times in modules: 000001b1401cdc20 t name_show 000001b0c05e6c40 t name_show [mdev] 000001b0c0495f30 t name_show [i2c_core] Fix this by changing the regular expression to only match the function name. Link: https://lore.kernel.org/all/20260909092954.2200558-1-svens@linux.ibm.com/ Fixes: 03b80ff8023a ("selftests/ftrace: Add new test case which checks non unique symbol") Signed-off-by: Sven Schnelle <svens@linux.ibm.com> Reviewed-by: Steven Rostedt <rostedt@goodmis.org> Signed-off-by: Masami Hiramatsu (Google) <mhiramat@kernel.org>
Diffstat (limited to 'Documentation/ABI/testing/sysfs-class-led-flash')
-rw-r--r--Documentation/ABI/testing/sysfs-class-led-flash89
1 files changed, 89 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-led-flash b/Documentation/ABI/testing/sysfs-class-led-flash
new file mode 100644
index 000000000..11e5677c3
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-class-led-flash
@@ -0,0 +1,89 @@
+What: /sys/class/leds/<led>/flash_brightness
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read/write
+ Set the brightness of this LED in the flash strobe mode, in
+ microamperes. The file is created only for the flash LED devices
+ that support setting flash brightness.
+
+ The value is between 0 and
+ /sys/class/leds/<led>/max_flash_brightness.
+
+What: /sys/class/leds/<led>/max_flash_brightness
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read only
+ Maximum brightness level for this LED in the flash strobe mode,
+ in microamperes.
+
+What: /sys/class/leds/<led>/flash_timeout
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read/write
+ Hardware timeout for flash, in microseconds. The flash strobe
+ is stopped after this period of time has passed from the start
+ of the strobe. The file is created only for the flash LED
+ devices that support setting flash timeout.
+
+What: /sys/class/leds/<led>/max_flash_timeout
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read only
+ Maximum flash timeout for this LED, in microseconds.
+
+What: /sys/class/leds/<led>/flash_strobe
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read/write
+ Flash strobe state. When written with 1 it triggers flash strobe
+ and when written with 0 it turns the flash off.
+
+ On read 1 means that flash is currently strobing and 0 means
+ that flash is off.
+
+What: /sys/class/leds/<led>/flash_fault
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read only
+ Space separated list of flash faults that may have occurred.
+ Flash faults are re-read after strobing the flash. Possible
+ flash faults:
+
+ * led-over-voltage
+ flash controller voltage to the flash LED
+ has exceeded the limit specific to the flash controller
+ * flash-timeout-exceeded
+ the flash strobe was still on when
+ the timeout set by the user has expired; not all flash
+ controllers may set this in all such conditions
+ * controller-over-temperature
+ the flash controller has
+ overheated
+ * controller-short-circuit
+ the short circuit protection
+ of the flash controller has been triggered
+ * led-power-supply-over-current
+ current in the LED power
+ supply has exceeded the limit specific to the flash
+ controller
+ * indicator-led-fault
+ the flash controller has detected
+ a short or open circuit condition on the indicator LED
+ * led-under-voltage
+ flash controller voltage to the flash
+ LED has been below the minimum limit specific to
+ the flash
+ * controller-under-voltage
+ the input voltage of the flash
+ controller is below the limit under which strobing the
+ flash at full current will not be possible;
+ the condition persists until this flag is no longer set
+ * led-over-temperature
+ the temperature of the LED has exceeded
+ its allowed upper limit